ARTECO-EVERYWHERE 3.0
Pag. 43
V 3.0 – 23/06/20 Rev 1.0
http://192.168.10.143/var.cgi?true=z
Set the status of a label to FALSE:
http://192.168.10.143/var.cgi?false=a
http://192.168.10.143/var.cgi?false=b
http://192.168.10.143/var.cgi?false=c
.......
http://192.168.10.143/var.cgi?false=z
The response to the command "DONE" is the string.
“input” Command
The "input" command allows you to excite an input for an Everywhere on which the command is directed.
It allows you to obtain the same effect that would occur if the selected input were physically connected to + 12V;
along with the corresponding LED lights. No voltage appears at the terminal of the effect for this command
input, the use of which is possible even if the input terminal is connected with a physical connection
simultaneously: in this case, the module "sees" the OR of the physical signal and the simulated one. This
means that if you send the "input" command to energize an input module, it will see the same input always
active until it will not send the command to put the same input to OFF, regardless of the input physical drive.
The command syntax is:
Set the status of a TRUE input:
http://192.168.10.143/input.cgi?ch-set=0
http://192.168.10.143/input.cgi?ch-set=1
http://192.168.10.143/input.cgi?ch-set=2
.......
http://192.168.10.143/input.cgi?ch-set=7
Set the status of a FALSE input:
http://192.168.10.143/input.cgi?ch-reset=0
http://192.168.10.143/input.cgi?ch-reset=1
http://192.168.10.143/input.cgi?ch-reset=2
.......
http://192.168.10.143/input.cgi?ch-reset=7
The response to the command is:
--Arteco Content-Type: text / plain O0H O1H O2H O3L O4L O5L O6L O7L I0H I1L I2L I3L I4L I5L I6L I7L