ARTECO-EVERYWHERE 3.0
Pag. 7
V 3.0 23/06/20 Rev 1.0
WIRING
Everywhere has dry contact inputs.
If you need to connect a device equipped with relay or "dry-contact" outputs, it can be connected
directly to the module input. See image below.
If a device with a digital voltage output (12/24 Vdc) is to be connected, an external relay must be used
1. Connect the output of the device to the relay input coil
2. Connect the relay output between the input pin and the common input
Things to take into account when connecting the device:
The conductor cross section must be adequate.
o For the device’s power supply to the P1 Connector, use cables with a minimum diameter of 0.5
mm²
o Use the same wire type as conductors for the P3 and P4 connectors.
o Depending on the type of installation, you may have to take into account other
recommendations. The installer is required to comply with all provisions that apply in the
country where the device is used.