33
12. Lights and alarms
ON/OFF
PILOT
LIGHT
(6)
TEMPERATURE
PILOT LIGHT
(13)
STEAM
PILOT
LIGHT
(12)
SCREEN
(21)
Coffee mode
Start-up ON Flashing 1Hz OFF Real reading
Heating ON Flashing 1Hz OFF Pre-set
coffee temp
Ready to work ON ON OFF Pre-set
coffee temp
Steam mode
Steam mode
(heating)
ON ON Flashing
1Hz
Pre-set
steam temp
(Flashing)
Steam mode
(start-up warning)
ON ON Flashing
2Hz
Pre-set
steam temp
Steam mode
(in service)
ON ON ON Pre-set
steam temp
On ending
steam mode
(cooling)
ON Flashing 1Hz ON Pre-set
coffee temp
(Flashing)
Others
Stand-by mode ON OFF OFF —
Dose control
fault
ON OFF Flashing
2Hz
E01
Coffee temp.
Probe fault
ON Flashing 2Hz Flashing
2Hz
E02
Coffee
exchanger fault
ON Flashing 4Hz Flashing
2Hz
E03
Steam temp.
Probe fault
ON Flashing 2Hz Flashing
2Hz
E04
Steam
exchanger fault
ON Flashing 2Hz Flashing
4Hz
E05
Internal fault ON OFF OFF E98
ENGLISH