EasyManuals Logo

Asco 4000 series Operator's Manual

Asco 4000 series
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Operator’s
Manual
4000 Series ATS
Automatic Open-Transition Transfer Switches
D–design 30–230A, J–design 260–600A,
H-design 800–1200A, G-design 1600–4000A, F-design 4000A
Florham Park, NJ 07932-1591 USA
Call 1 800 800-2726 (ASCO) for sales or service www.ascopower.com
ASCO POWER TECHNOLOGIES CANADA PO Box 1238, 17 Airport Road, Brantford, Ontario, Canada N3T 5T3
DANGER is used in this manual to warn of a
hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING is used in this manual to warn of a
hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION is used in this manual to warn of a
hazardous situation which, if not avoided, could
result in minor or moderate injury.
Refer to the outline and wiring drawings provided with your
4000 Series ATS for all installation and connection details
and accessories.
Refer to Group 5 Controller User’s Guide 381333–126 for
ATS status display messages, time delays, pickup &
dropout settings, and adjustments.
An experienced licensed electrician must install the ATS
.
Rating Label
Each automatic transfer switch contains a rating label to
define the loads and fault circuit withstand / closing ratings.
Refer to the label on the transfer switch for specific values
Do not exceed the values on the rating label.
Exceeding the rating can cause personal injury
or serious equipment damage.
381333-270 D
TABLE OF CONTENTS
page
Ratin
g
Label 1
Nameplate, Catalo
g
Number Identification 2
INSTALLATION
3-7
Removing the Shipping Skid, Supporting
Foundation, Mounting, Testing Power
Conductors,
3
Connecting Power Conductors, Auxiliary Cable
Boxes, Bus Connections, Controller Ground,
Harnesses, En
g
ine Startin
g
& Auxiliar
y
Circuits
4
En
g
ine Startin
g
Contacts 5
Functional Test 6-9
Functional Test
Manual Operation Test 6
Functional Test
Volta
g
e Checks
8
Functional Test - -Electrical Operation
9
TESTING & SERVICE
10-11
Transfer Test, Preventive Maintenance,
Replacement Parts, Disconnecting the Controller
10
Manual Load Transfer, Trouble-Shootin
g
11
INDEX
12

Other manuals for Asco 4000 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Asco 4000 series and is the answer not in the manual?

Asco 4000 series Specifications

General IconGeneral
TypeSolenoid Valve
Series4000
Amperage RangeVaries by model
VoltageVaries by model (AC and DC options available)
PolesNot applicable
Switch TypeNot applicable
Control PanelNot applicable
MediaAir, Water, Oil
Orifice SizeVaries by model
Pressure RangeVaries by model
Body MaterialBrass, Stainless Steel, Aluminum
Seal MaterialVaries by model (e.g., NBR, FKM, EPDM)
OperationDirect Acting, Pilot Operated
Function2-Way, 3-Way
Temperature RangeVaries by model
Port SizeVaries by model (NPT or BSPP)