General Data - Cooling Only
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING IS BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
Btu/h
W
W
A
V/Ph/Hz
W/ W
CFM /
l
/s
CFM /
l
/s
CFM / l /s
dBA
mm/in
mm/in
mm/in
mm/in
mm/in
mm/in
kg/lb
mm/in
CFM / l /s
dBA
mm/in
mm/in
mm/in
mm/in
mm/in
mm/in
kg/lb
LIQUID mm/in
GAS mm/in
kg/lb
19.05 / 3/4
FLARE
50 / 110
983 / 38.7
405 / 15.9
328 / 12.9
785 / 30.9
4 WAY AUTOMATIC LOUVER (UP & DOWN)
WIRELESS OR WIREDE MICROCOMPUTER REMOTE CONTROL
630 (700) / 24.8 (27.6)
630 (700) / 24.8 (27.6)
A5LCX 20C
A5CKX 20C
5,275 (1,465 - 5,862)
18,000 (5,000 - 20,000)
1,646 (497 - 1,856)
1.3 / 2.86
12.7 / 1/2
6.35 / 1/4
53
757 / 6.67
1500 / 708
23 + 2 / 50.7 + 4.4
250 (295) / 9.8 (11.6)
570 (640) / 22.4 (25.2)
DEPTH
WIDTH
HEIGHT
TYPE
UNIT WEIGHT
PIPE CONNECTION
SIZE
PACKING
DIMENSION
HEIGHT
NOMINAL COOLING CAPACITY
INDOOR UNIT
OUTDOOR UNIT
MODEL
NOMINAL TOTAL INPUT POWER
NOMINAL RUNNING CURRENT
AIR FLOW
INDOOR UNIT
CONTROL
MEDIUM
POWER SOURCE
REFRIGERANT CONTROL (EXPANSION DEVICE)
CONDENSATE DRAIN SIZE
AIR DISCHARGE
OPERATION
OUTDOOR UNIT
UNIT DIMENSION
() - WITH PANEL
DEPTH
UNIT WEIGHT (UNIT + PANEL)
PACKING
DIMENSION ()
- PANEL
HEIGHT
WIDTH
SOUND PRESSURE
UNIT DIMENSION
REFRIGERANT CHARGE
HIGH
LOW
DEPTH
HEIGHT
WIDTH
DEPTH
WIDTH
SOUND PRESSURE (H/M/L)
AIR FLOW
7.23 (2.10 - 8.12)
47 / 46 / 44
450 / 212
855 (+70) / 33.7 (+2.7)
410 / 194
430 / 203
570 (640) / 22.4 (25.2)
317 (127) / 12.5 (5)
230 /1/ 50
OUTDOOR EXV
R410A
EER 3.2
REFRIGERANT TYPE