6
© 2023 United States Stove Company
INSTALLATION
INSTALLATION ITEMS
1. Remove all items from the carton. Remove
all packing materials applied to the heater for
shipment.
2. Check the heater for shipping damage. If the
heater is damaged, promptly inform USSC at
(800) 750-2723.
Material To Be Removed
Figure 5
Minimum Clearance From Combustible
Construction
Rear 0.25 inches (with supplied spacers)
Sides 6 inches
Top 36 inches
Floor 6 inches
CEILING
36”
(914 mm) Min.
6”
(152 mm) Min.
6”
(152 mm) Min.
FLOOR
Figure 6
PRODUCT FEATURES
Model No.
Input * Btu/Hr.
(kW)
Max. Gas Inlet
Pressure inch
W.C. (mm. W.C.)
Min. Gas Inlet
Pressure inch
W.C. (mm. W.C.)
Pres. Reg.
Settings
Manifold inch
W.C. (mm. W.C.)
Valve Type
DVAG11-DF (LP)
DVAG11-DF (NG)
DVAG17-DF (LP)
DVAG17-DF (NG)
DVAG25-DF (LP)
DVAG25-DF (NG)
**NOTE: Minimum Gas Inlet Pressure for purpose of input adjustment. The efciency rating of the
appliance is a product thermal efciency rating determined under continuous operating conditions and
was determined independently of any installed system.