Electrical
A separate electrical service is not required for the washer.
The receptacle for the washer is located on the back of the
dryer.
If the washer is being installed separate from the dryer, refer
to the electrical requirements below. The electrical location
must be placed within reach of the power cord.
Installation must comply with all applicable electrical codes.
ELECTRICAL REQUIREMENTS
WASHER
Electrical Supply grounded, 220 VAC, 60 Hz
Service 15 amp
Receptacle NEMA 6–20R grounding-type
Power Cord 6'
(1.8 m)
DRYER
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 30 amp
Plumbing
Installation must comply with all applicable plumbing codes.
PLUMBING REQUIREMENTS
Water Connection
1
/2" ID min (cold only)
Pressure 15–146 psi
(1–10 bar)