18
5.5 Program flow description
Presented below is the Quick program. If the component test in the service menu is not sufficient to
identify a fault you can run this program and compare the results with the flow description below. If they
are in agreement this indicates a correctly functioning control unit.
Component Time Comments
Main wash
Drainage pump 6 sec. 25 sec. if the previous program was cancelled
with the Start/Stop button
Inlet valve 40/45 sec. With/without diverter
Circ. pump 30 sec.
Circ. pump & Combi dispenser 3 sec.
Circ. pump 120 sec.
Circ. pump & Element T-30º/35º Eco/Normal temp
Circ. pump 180 sec.
Circ. pump & Element T-30º/60º Eco/Normal temp
SCS 22 sec. Super Clean System
Drainage pump 25 sec.
1st rinse
Inlet valve 7 sec.
Circ. pump 2 sec.
Pause 5 sec.
Circ. pump 2 sec.
Drainage pump 6 sec.
Inlet valve 40/45 sec. With/without diverter
Circ. pump 90 sec.
SCS 22 sec. Super Clean System
Drainage pump 25 sec.
Final rinse
Inlet valve 40/45 sec. With/without diverter
Circ. pump & Element T-0/60º Eco/Normal drying
Circ. pump & Combi dispenser 3 sec. None Eco drying
Circ. pump 3 sec. No Eco drying
Circ. pump & Combi dispenser 60 sec. No Eco drying
Circ. pump 90/60 sec. Eco/Normal drying
Pause 60 sec.
Drainage pump 25 sec.
Fan 600 sec. Normal drying
PROGRAMS AND CONTROL UNIT