EasyManua.ls Logo

Aspen LCM-Twin T38 User Manual

Aspen LCM-Twin T38
25 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
24 St. Martin Dr.
Marlborough, MA 01752
Installation and Operation Instructions
LCM-Twin T38
FP00066, FP00102
Installations Notes
Date of Purchase
Date of Installation
Installer
Model Number
Serial Number
Question and Answer IconNeed help?

Do you have a question about the Aspen LCM-Twin T38 and is the answer not in the manual?

Aspen LCM-Twin T38 Specifications

General IconGeneral
CategoryControl Unit
Touch ScreenYes
Power Supply24 VDC
Humidity Rangenon-condensing
Communication PortsEthernet
Display TypeTFT LCD

Summary

System Information and Safety

System Overview

Describes the LCM-1400 as a chassis-mounted cooling system.

Safety Guidelines

General safety warnings including refrigerant contact, frostbite, and hot components.

General Operation and Installation

Environmental and Physical Specifications

Coolant, ambient operating/storage temperatures, weight, and dimensions.

Condenser Fan and Airflow

Details on condenser fans, power supply, and airflow requirements.

Fluid Connections

Information on push-to-connect fittings and coolant flow.

Mounting Instructions

Instructions for mounting the LCM unit using its base plate.

Power Supply, Compressor Control, and Performance

Power Supply Requirements (FP00066/FP00102)

Voltage range, current draw, and wire gauge for 48 VDC and 24 VDC models.

Thermal Switch Functionality

Description of the thermal switch for compressor overheat protection.

Compressor Control System Details

Introduction to the BLDC drive, speed control, and input signals.

System Performance Map

Performance curves for cooling capacity vs. coolant temperature.

Maintenance and Customer Support

Condenser Maintenance

Instructions for cleaning condenser fins to ensure efficiency.

Commercial Product Warranty

Details of the limited warranty for Aspen products.

Warranty Repair Process

Procedure for obtaining warranty repairs and returning products.

Technical Support and Contact

Information on obtaining technical assistance and contact details.

Aspen Compressor BLDC Drive Operation

Drive Modes and Jumper Configuration

Details on Mode 1 (Direct Replacement) and Mode 2 (Quiet Sinusoidal) operation.

Drive Connections and Wiring

Explanation of terminal connections (TB5-TB16) and recommended wiring.

Condenser Fan Output Fusing

Recommended fuse sizes for the condenser fan output.

Compressor Speed Control Options

Details on speed input methods (0-5V, 0-10V, 4-20mA, Frequency) for Mode 2.

Jumper Settings for Drive Modes

Tables for selecting jumper positions for specific drive functions and compressor types.

BLDC Drive Troubleshooting

Guide for diagnosing and resolving common drive symptoms and error codes.