COOKER HOOD
INSTRUCTION MANUAL
Read this manual carefully before operation
Pictures in this manual are for reference only, the product in kind prevail.
ACT1680
ACT1780
ACT1980

Questions and Answers

  • J
    Jack ValdezAug 9, 2025
    Why does my Aspes Ventilation Hood have insufficient suction?
    • C
      Caitlin NicholsAug 9, 2025
      If your Aspes Ventilation Hood isn't providing enough suction, it might be because the distance between the hood and your cooker top is too great. Try readjusting the distance. Also, too much ventilation from open doors or windows can affect suction. Consider installing the appliance in a different location or closing some doors and windows.
  • J
    Jennifer KennedyAug 14, 2025
    What to do if my Aspes Ventilation Hood is vibrating?
    • J
      Jerry WhiteAug 14, 2025
      If your Aspes Ventilation Hood is vibrating, consider these potential causes: * A damaged blade could be the culprit; if so, replace the blade. * The motor might not be tightly fastened; ensure it is securely tightened. * The cooker hood itself might not be tightly fixed; make sure it is properly secured.
  • M
    Melinda HawkinsAug 19, 2025
    How to fix an Aspes Ventilation Hood when the light is on, but the motor doesn't work?
    • M
      Meagan MorrowSep 12, 2025
      If the light on your Aspes Ventilation Hood is on but the motor isn't working, there could be several reasons. The blades might be blocked, in which case you should check them. Alternatively, the capacitor or the motor itself may be damaged, requiring replacement. It's also possible that the internal wiring of the motor is cut off or disconnected; in this case, replace the motor.
  • M
    margaretbradfordAug 23, 2025
    What to do if both the light and motor don't work on my Aspes Ventilation Hood?
    • O
      Oscar SmithAug 23, 2025
      If both the light and motor on your Aspes Ventilation Hood aren't working, it could be due to a damaged light, which would need replacing. Another possibility is a loose power cord. In this case, connect the wires according to the electrical diagram.
  • L
    Leslie RomeroAug 29, 2025
    Why is my Aspes Ventilation Hood inclining?
    • M
      Martin VegaAug 29, 2025
      If your Aspes Ventilation Hood is inclining, it's likely that the fixing screws or the hanging screws are not tight enough. Tighten the fixing screw and the hanging screw to make it horizontal.
  • J
    Jennifer TorresSep 3, 2025
    How to stop oil from leaking from my Aspes Ventilation Hood?
    • D
      deborahsanchezSep 3, 2025
      If you're experiencing oil leakage from your Aspes Ventilation Hood, the outlet and air ventilation entrance may not be tightly sealed. To resolve this, take down the outlet and seal it with glue.

Aspes ACT1680 Specifications

General IconGeneral
TypeWall-mounted
Width60 cm
Number of motors1
Maximum extraction power380 m³/h
Number of speeds3
Control typeMechanical
MaterialStainless steel
Filter typeAluminum grease filter