12/04/2016 - 20 - Concept
10.2 Do’s
Do test the location and the number of hub’s needed on side before fixing them to the wall.
The number of hub’s are very dependent on the building, it’s interior and the overall environment.
The number of hub’s cannot be defined in advance or on paper…
Do install the hub in a vertical position on the wall.
10.3 Don ‘ts
Do not install the hubs outside.
Do not install a hub near metallic elements.
Do not install a hub near structure cables.
Do not install a hub inside a false ceiling.
Do not install a hub within a distance of 3 meters of a Wi-Fi Network Access Point.
Do not install a hub within a distance of 5 meters of a microwave source.
Do not install a hub when mirrors are between the hub and the lock (mirrors reflect the signals).
Do not install hubs when more than two walls are between the hub and the device.
Do not install readers on a metallic surface.
Do not install the hub on the ceiling.