EasyManua.ls Logo

Astralpool 42350 - Page 13

Astralpool 42350
105 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
5.3. Production level selection
To select the desired production level, press the
-” [1] / “+” [14] keys until the production level light blinks. The system information screen [11]
will display the value of the production scale light [4]. The system will set its production to the desired level after a few seconds.
Fig. 20
In normal conditions, the production value [4] should be the same as the programmed value. If the salt level in the water is outside the permitted
range (“HIGH SALT” [7] or “LOW SALT” [6] alarms on), or there is a problem in the electrolysis cell (“ELECTRODES” [13] alarm on), however,
the production value [4] could be lower than the programmed and displayed value [11].
5.4. Salinity test
AstralPool Chlore Smart + systems have an integrated system to detect the salinity level of pool water. To run the test, press the “SALT TEST”
[9] key. During the test, the production light will range from 20%-80% of the salinity scale [5], alternately displaying “SALT” and “TEST” on the
system information screen [11]. Once the test is completed, the light will blink for a few seconds on the scale [5] on the detected salinity value
(see Fig. 21). The equipment will return to normal operating mode after a few seconds.
Fig. 21
The system might show lower than actual salt levels if the temperature falls beneath 20