EasyManua.ls Logo

Astralpool Energy Sel 55 User Manual

Astralpool Energy Sel 55
44 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Vers.20181212
Energy Sel Series
Energy Sel
Models
Energy Sel 30
Energy Sel 55
Energy Sel 95
Astralpool
EN
ES
FR
IT
DE
PT
Manual de Instalação e de Utilização
Installations - und Gebrauchshandbuch
Manuale d’installazione e d’utilizzo
Manual de instalación y utilización
Installation and User Manual
Notice d’installation et d’utilisation
CODE:101275
Question and Answer IconNeed help?

Do you have a question about the Astralpool Energy Sel 55 and is the answer not in the manual?

Astralpool Energy Sel 55 Specifications

General IconGeneral
Power55W
Light SourceLED
Beam Angle120°
IP RatingIP68
Lifespan50, 000 hours

Summary

Important Safety and Disposal Information

User Restrictions

Machine should not be used by persons with reduced physical, sensory, or mental abilities, or those lacking experience, without supervision.

Recommendations for Optimal Operation

Salt Concentration and pH

Recommended salt concentration (4.0 g/l) and pH (7.0-7.4) for proper functioning.

TAC and Stabilizer Levels

Recommended TAC (12-18°F) and stabilizer (20-50 g/m³) levels for pool water.

Water Temperature and Chlorine Concentration

Do not operate below 15°C; recommended chlorine concentration is 0.5-2.5 ppm.

Installation and Electrical Connections

Unit Power Supply

Connection: 230V, 50/60Hz, 70W max. Must run with filtration pump.

Commissioning and Operation

Stabilizer Usage and Limits

Use 10-20 g/m³ stabilizer; too low doubles chlorine use, too high cancels effect.

Adding Salt Procedure

Add salt to pool while filtration runs; wait for dissolution. Dosage: 4g/l.

Initial Start-up

Turn on, adjust to max production, run filtration 24/24 until 0.5 ppm chlorine.

Production Adjustment and Monitoring

Switch filtration to auto, check chlorine, adjust if needed. Electrode powers up after delay.

Grounding and Usage Tips

Chlorine and pH Testing Methods

Test weekly; chlorine (0.5-2.5 ppm) and pH (7.0-7.4) are volatile.

Advanced Adjustments and Maintenance

Reverse Polarity Time Adjustment

Factory set to 4 hours; adjustable 1-99 hours based on water hardness (TH).

Electrode Maintenance Tips

Never run below 3.5 g/l salt. Turn off below 15°C. Avoid max production unless needed.

Troubleshooting and Electrode Care

Electrode De-scaling

De-scale with 80% water, 20% HCl solution. Check for high pH, low salt, long polarity change, or worn electrode.

Indicator On, Production Off

Machine is in safety mode due to high current, voltage, or temperature.

Failure to Reach Electric Current Set-point

Check salt concentration, water temperature, and electrode condition (clean, no scale).