9
Maintenance
Press and hold
2s to turn o the
appliance
Disconnect the
power supply for
at least 3 minutes
Close valves A
and C and open
valves D and E (if
present)
Drain the
water from the
condenser to
avoid any risk of
freezing
Put on the winterising cover
• ln the case of full winterising for the pool (complete shutdown of the ltraon system, bleed the ltraon
circuit or even pool drainage): re-t the two connectors by one turn to prevent any foreign bodies from
geng into the condenser.
• ln the case of winterising for the heat pump only (shutdown of the heang only, the ltraon keeps
running): do not ghten the connectors but add 2 caps (provided) on the condenser’s water inlets and
outlets.
• Put on the winterising cover (provided) on the heat pump passing the hydraulics connecons up through the
opening provided for that purpose. It is not necessary to disconnect hydraulic and electrical connecons.
Winterising
• Winterising is vital to prevent the condenser breaking due to freezing (freezing without winterising
is not covered by the warranty).
• To avoid damaging the appliance with condensaon, do not fully caver it; use the provided
winterising cover.
• Do not disconnect the electricity supply when the appliance is running. If the electric power
supply is interrupted, wait a minute before restoring power to the appliance.
• Before any maintenance, troubleshoong or repair operaon, deacvang the modem’s Wi-Fi
connecon is recommended to avoid any risk of the appliance being remotely controlled.
• lt is recommended that the appliance undergo general servicing at least on a yearly basis to
ensure proper operaon, maintain performance levels and potenally prevent certain failures.
These operaons are carried out at the user’s expense by a technician.
❸
Maintenance
Refer to the online manual for
further details about safety
instrucons relave to R32
refrigerant and maintenance tasks
that have to be carried out by a
qualied technician.
Maintenance
• Make sure that the venlaon grid is not blocked by any foreign bodies.
• Clean the evaporator using a so brush and a fresh water spray (disconnect the power cable).
• Clean the condensate drainage line to remove any impuries that may be blocking it.
• Make sure that the switch box’s venlaon grid is clean.
• Do not use a high pressure jet. Do not spray with rain water, salt water or water which is full of minerais.
• Clean the outside of the appliance; do not use any solvent-based products. You can use a specic
cleaning kit as an accessory: the PAC NET.
6