Parameter Manual Description App Description Range Default Remark
19
Setting ofheat exchange ice
protection Tout
( too low water ow)
Protection water outlet
temp. cooling
3 ~ 20°C 5°C Adjustable
20
Protection setting of
In-Out water temperature
Protection In-Out water 5 ~ 20°C 13°C Adjustable
21
Protection water outlet temp.
heating
Protection water outlet
temp. heating
20~ 90°C 60°C Adjustable
22
Time delay of compressor start
(after lter pump start)
Delay of compressor start 5 ~ 99S 60S Adjustable
23
Time delay olter pump stop
(after compressor stop)
Delay of lter pump stop 5 ~ 99S 30S Adjustable
24
Setting Ambient temp. to Start
bottom heater
Bottom Heater Start 0 ~ 20°C 7°C Adjustable
25
Setting Ambient temp. to change
fan speed
Setting Fan Speed Temp 5 ~ 40°C 27°C Adjustable
26 Change Fahrenheit/C(0=C/1 =F) Fahrenheit /C 0(C)/l(F) 0 Adjustable
27 Factory reset Factory Reset
0(Reset)/
l(Existing
Setting)
1 Adjustable
Parameter table overview (2/2)
Remarks: To change the factory default via the phone, password is required and only available for
technician.
* Run 5m in /2 hr = lt er pump runs 5 min every 2 hours checking inlet temp., will run for 5 min, in this
period will disregard the ow switch.
** (O = m a nua l, in manual parameter 13 and 14 is enabled/ l=auto ma tic , in Automatic parameter 13
disabled only Parameter 12 & 14 is valid.)
Remarks: "
┌
" =" T", e.g. "
┌
0" = T 0".
Parameter Description Range Remark
T0 Water inlet temp. -9 ~ 99°C Measured Value
T1 Water outlet temp. -9 ~ 99°C Measured Value
T2 Evaporator coi! temp. -9 ~ 99°C Measured Value
T3 Ambient temp. -9 ~ 99°C Measured Value
T4 Compressor receiver temp. -9 ~ 99°C Measured Value
T5 Opening ofEEV 10 ~ 50 (1 =10P) Measured Value
T6 Not used -9 ~ 99°C Measured Value
T7 Not used -9 ~ 99°C Measured Value
System measure value overview (2)