• Connect the test leads to both ends of the circuit or resistor
under test (parallel). If the resistance of the circuit or resistor
under test is connected and less than 50Q, the buzzer will
emit a beep sound
• If the circuit or resistor under test is disconnected,
or the resistance value is greater than 50Q, the
LCD screen will display "1
• Turn the rotary switch to the OFF position to turn off the Meter.
VI DIODE TEST:
• Insert the red test lead into the "VQmASIT" terminal and the black
test lead into the "COM" terminal
• Turn the rotary dial to the " " setting. touch
the red and the black test leads to check
whether they are normal. The buzzer will beep
if the test leads are normal
• Connect the red test lead to the anode of the diode under test
and the black test lead to the cathode of the diode
NOTE:
(j) Usually the anode of the diode is the longer end
• The LCD screen will display the approximate voltage drop
reading of the diode. The test unit is "mV". If the test leads are
connected in reverse, "1" will be displayed on the LCD screen.
Please replace the test leads to measure again.
• Turn the rotary switch to the OFF position to turn off the Meter.
-18