10
-
Input Impedance: 10MΩ
Input Impedance: 10MΩ
Overload Protection: 600V AC RMS CAT III, 1000V AC
RMS CAT II
Max. Input voltage: 600V AC RMS CAT III, 1000V AC RMS
CAT II
show True-RMS value
5-4. TEMPERATURE
Range
Resolution
Accuracy
-40 ~
1370°C
1°C
-40°C~150°C:±(1% + 4)
150°C~1370°C:±(2% + 3)
-40 ~
2000°F
1°F
-40°F~302°F:±(5% + 4)
302°F~2000°F:±(2.5% + 4)
Overload Protection: 250V DC/AC rms
5-5. RESISTANCE (Auto Ranging)
Range
Resolution
Accuracy
600Ω
0.1Ω
±(1.5% of rdg + 5dgts)
6KΩ
60KΩ
10Ω
600KΩ
100Ω
6MΩ
1KΩ
60MΩ
10KΩ
Open Voltage: about 0.25V
Overload Protection: 250V DC/AC RMS
5-6. Diode and Continuity
Range
Introduction
Remark
The approximate forward
voltage drop will be
displayed
Open circuit
voltage: about
1.5V

Related product manuals