5. SPECIFICATIONS
Accuracy is guarantied for 1 year 23°C±5°C less than
80%RH
5-1. DC VOLTAGE (Auto ranging)
Input Impedance: 10MΩ
Range
Resolution
Accuracy
600mV
0.1mV
±(0.8% of rdg + 5dgts)
6V
1mV
±(0.8% of rdg + 3dgts)
60V
10mV
600V
100mV
1000V
1V
±(1.0% of rdg + 5dgts)
Overload Protection:
600V AC RMS CAT III, 1000V AC RMS CAT II
Max. Input voltage:
600V AC RMS CAT III, 1000V AC RMS CAT II
5-2. AC CURRENT (Auto ranging)
Measuring voltage drop: 200mV
Range
Resolution
Accuracy
60A
10mA
±(2.5% of rdg + 10dgts)
600A
100mA
1000A
1A
show True-RMS value
5-3. AC VOLTAGE (Auto ranging)
Range
Resolution
600mV
0.1mV
6V
1mV
60V
10mV
600V
100mV
750V
1V