Q-CodeLoggerallowsyoutoeasilycheckQ-Codeeventlogswithoutopeningthesystem’s
case.
TousetheQ-Codelogger:
1. InserttheUSBstoragedevicetothededicatedQ-CodeloggerUSBport.
2. PresstheQ-CodeloggerbuttonforthreesecondsuntiltheFlashbackLEDblinksthree
times,indicatingthattheQ-Codeloggerfunctionisenabled.
Using the USB Flashback
USBBIOSFlashbackallowsyoutoeasilyupdatetheBIOSwithoutenteringBIOSor
operating system.
TouseUSBFlashback:
1. DownloadthelatestBIOSlefromtheASUSwebsite.
2. ExtractandrenametheBIOSimageletoZ10PEWS.CAP.
3. CopyZ10PEWS.CAPtotherootdirectoryofyourUSBstoragedevice.
4. TurnoffthesystemandconnecttheUSBstoragedevicetotheUSBBIOSFlashback
port.
5. PresstheUSBBIOSFlashbackbutton.
AashinglightindicatesthattheBIOSFlashbackfunctionisenabled.Thelightgoesout
whentheprocessofupdatingtheBIOSiscomplete.
USB BIOS Flashback port