The Bio-Logic® Germicidal Ultraviolet Water Purifier is a device designed to purify water using ultraviolet (UV) light. It is available in two models, BIO 1.5 and BIO 3.0, and is intended for indoor use only. The purifier utilizes germicidal ultraviolet rays to inactivate bacteria and other microorganisms in water, providing a chemical-free method of water purification.
The Bio-Logic® purifier operates by exposing water to germicidal UV light as it flows through a stainless steel chamber. The UV light, specifically at a wavelength of 254 nm, disrupts the DNA of microorganisms, rendering them unable to reproduce and effectively sterilizing the water. The system is designed for point-of-use (POU) applications, meaning it should be installed as close as possible to the point where purified water is needed to minimize the chance of re-contamination.
The purification process involves water entering the chamber and flowing past a quartz sleeve, which encases the germicidal UV lamp. The UV intensity and exposure time are critical for effective purification. The system is designed to provide adequate germicidal dosage throughout the disinfection chamber.
| Model | BIO 1.5 | BIO 3.0 |
|---|---|---|
| Flow Rate (GPM) | 1.5 | 3.0 |
| Inlet/Outlet Size | 3/8"FNPT | 3/8"FNPT |
| Number of Lamps | 1 | 1 |
| Lamp Model No. | 05-1366-R | 05-1370-R |
| Quartz Sleeve | 1 | 1 |
| Length | 14-1/2" | 20-1/8" |
| Width | 3-21/32" | 3-21/32" |
| Height | 3-7/8" | 3-7/8" |
| Voltage | 120V 50/60Hz or 230V 50/60Hz | 120V 50/60Hz or 230V 50/60Hz |
| Chamber Diameter | 2-7/16" | 2-7/16" |
| Shipping Weight | 7.2 lbs. | 7.7 lbs. |
| Power Consumption | 14 Watts | 21 Watts |
| Max Operating Pressure | 100 PSI | 100 PSI |
| Ambient Temperature | 35°F-100°F | 35°F-100°F |
The system requires specific power requirements: 120V 50/60Hz (ballast no. 10-0518A) or 230V 50/60Hz (ballast no. 10-0514A). It is crucial that the electrical power supplied matches these requirements. A voltage surge protector is recommended.
Water quality is a critical factor for the effective operation of the UV purifier. The maximum concentration levels for various parameters are specified:
The Bio-Logic® purifier is designed for horizontal mounting and should be located in a dry, well-lit area with adequate clearance for maintenance. It must be protected from elements and temperatures below freezing (ambient temperature between 35°F and 100°F).
Installation requires connecting the purifier to a grounded Ground Fault Circuit Interrupt (GFCI) receptacle. Metal piping is recommended for connections to the inlet and outlet for at least 12 inches past the first elbow to avoid UV degradation of plastic pipes.
Optional accessories are available to enhance the system's functionality:
Regular maintenance is essential for optimal performance and includes:
The manual emphasizes safety precautions, including always disconnecting power before servicing, avoiding direct or reflected UV exposure, and wearing appropriate protective gear (eyewear, face shield, gloves). It also advises against operating the purifier if any components are damaged or if there is no proper electrical ground.