EasyManua.ls Logo

Atlantic Ultraviolet Megatron M50 - User Manual

Atlantic Ultraviolet Megatron M50
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
Document No. 98-1854A1 • February 2023 • ©2023 Atlantic Ultraviolet Corporation
®
Models M50, M90, M150 & M250
Owner
s Manual
Owner
s Manual
Installation,
Operation &
Maintenance
Read and Follow All
Safety Instructions.
Save These Instructions.
Manufacturers / Engineers / Sales / Service
Germicidal Ultraviolet – Equipment & Lamps
375 Marcus Boulevard, Hauppauge, NY 11788
(631) 273-0500 • Fax: (631) 273-0771
Email: Sales@AtlanticUV.com
Shop Products at
AtlanticUltraviolet.com
———————————————
Learn More at Ultraviolet.com

Questions and Answers

  • K
    Kelly HunterAug 12, 2025
    Why is my Atlantic Ultraviolet Water Filtration System not operating?
    • F
      Frank ThompsonAug 12, 2025
      Your Atlantic Ultraviolet Water Filtration System might not be operating due to several reasons. First, ensure the system is properly connected to a functioning power source. Second, check the circuit breaker in the power distribution panel; if it has tripped, disconnect the system from the power source and inspect the wiring for any damage to electrical components. Lastly, verify that all power connections to the modules are securely connected.
  • W
    wmccartyAug 16, 2025
    What to do if multiple lamp indicators are not glowing green on my Atlantic Ultraviolet Water Filtration Systems?
    • L
      Leslie MortonAug 16, 2025
      If multiple lamp indicators on your Atlantic Ultraviolet Water Filtration Systems are not glowing green, check the lamp-out cable connections to the ballast tray assembly and front panel assembly to ensure they are securely connected. Also, verify that the power cable from the power distribution panel and front panel are securely connected.
  • R
    Randy ColeAug 20, 2025
    What to do if all lamp indicators fail to glow green on my Atlantic Ultraviolet Water Filtration Systems?
    • L
      Leslie ThomasAug 20, 2025
      If all lamp indicators fail to glow green on your Atlantic Ultraviolet Water Filtration Systems, first ensure that all lamps are installed. Next, verify that the power cable from the power distribution panel to the ballast tray assemblies is securely connected. Finally, check that the lamp-out cable connections from the ballast tray assembly to the front panel assembly are also securely connected.
  • S
    stephaniejohnsonAug 25, 2025
    Why is the enclosure cooler blower not functioning in my Atlantic Ultraviolet Water Filtration System?
    • R
      Ralph LopezAug 25, 2025
      The enclosure cooler blower in your Atlantic Ultraviolet Water Filtration System might not be functioning due to a loose power connection. Check the blower's connections to the power distribution panel, ensuring they are tight and making full contact. If the connection is secure and the blower still doesn't work, the blower itself may be faulty and require replacement.
  • E
    emilyfloresAug 27, 2025
    What to do if a single lamp indicator is not glowing green on my Atlantic Ultraviolet Water Filtration System?
    • K
      Kenneth MyersAug 27, 2025
      If a single lamp indicator is not glowing green on your Atlantic Ultraviolet Water Filtration System, it could be due to several reasons. First, the germicidal lamp might not be operating. Disconnect the lamp socket from the non-operating lamp and connect a lamp socket from a known good lamp to it. If the lamp still fails to operate, replace it. Second, the germicidal lamp may not be properly connected; confirm the connection of the lamp socket and lamp, ensuring it is tight and making full contact. Third, the lamp's ballast may not be functioning. Disconnect the lamp socket from the non-operating lamp and reconnect it to a known good operating lamp. If the good lamp fails to operate, locate the ballast with the corresponding lamp number and replace it.
  • D
    Doris ThompsonAug 31, 2025
    What causes water leak from chamber fittings in Atlantic Ultraviolet Water Filtration System?
    • W
      William GeorgeAug 31, 2025
      If you notice a water leak from chamber fittings in your Atlantic Ultraviolet Water Filtration System, it may be due to loose or untightened plumbing, drain plug, test ports, or bolts. Shut off the water supply and depressurize the chamber. Remove any standing water around the unit and inspect the leaking area. Tighten any loose fittings. Re-apply Teflon® tape on any leaking fittings before reinstalling.
  • Y
    younglanceSep 4, 2025
    Why is the automatic quartz wiper system not functioning on my Atlantic Ultraviolet Water Filtration?
    • J
      James WrightSep 4, 2025
      If the automatic quartz wiper system is not functioning on your Atlantic Ultraviolet Water Filtration, verify that the cabling between the front panel assembly and wiper compressor assembly are securely connected. Also, review and confirm that the scheduled wiper program is properly set up and that the wiper controller is set to “RUN” mode. If the wiper controller is set to “MANUAL” mode, confirm that the scheduled wiper program is set to operate for only a 1-minute cycle time. If not, set mode to “OFF” mode for a period of 10 minutes before making any other selections.
  • A
    Allen GarzaSep 8, 2025
    What causes water leak from EASY-OFF™ End Cap in Atlantic Ultraviolet Water Filtration System?
    • J
      James PageSep 8, 2025
      A water leak from the EASY-OFF™ End Cap or Quartz Sleeve of your Atlantic Ultraviolet Water Filtration System can be caused by a broken end cap or broken quartz sleeve. To address this, disconnect the system from power, shut off the water supply, and depressurize the chamber. Remove any standing water around the unit and replace the quartz sleeves.

Atlantic Ultraviolet Megatron M50 Specifications

General IconGeneral
ModelMegatron M50
ManufacturerAtlantic Ultraviolet
CategoryWater Filtration Systems
Flow Rate50 GPM
Wavelength254 nm
Maximum Operating Pressure125 psi
UV Lamp TypeLow Pressure High Output
Electrical Requirements120V/60Hz or 220V/50Hz (depending on model)
Power Consumption150 Watts
CertificationsCE
Maximum Water Temperature40°C