EasyManua.ls Logo

Atlantic Panama 1000 - User Manual

Atlantic Panama 1000
124 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installation and
operating manual
Handleiding voor
installatie
Instrukcja instalacji
Montageanweisungen
for the professional
installerand the user
Bestemd voor professio-
nele installateurs
przeznaczona dla
profesjonalistów
für Fachleute
to be kept by the user for
later reference
Door de gebruiker te bewa-
ren voor later nazicht
Instrukcję należy zachować
na przyszłość
Für späteres Nachschlagen,
vom Benutzer
aufzubewahren
www.atlantic.fr
Panama
Dynamic Radiator
Dynamische radiator
Grzejnik dynamiczny
Dynamischer Heizkörper
Panama 500 : 080461
Panama 1000 : 080471

Table of Contents

Questions and Answers

  • E
    Eric ValdezAug 16, 2025
    Why doesn't my Atlantic Heater work and the signal lamps are all off?
    • S
      Stephanie BoydAug 16, 2025
      If your Atlantic Heater isn't working and all the signal lamps are off, it could be due to a lack of power. First, try turning it on again using the circuit breaker. If that doesn't work, press the power button on the appliance. If the issue persists, contact After Sales service or your installer.
  • S
    Sandra WestAug 19, 2025
    Why is my Atlantic Panama 1000 not heating or cooling sufficiently?
    • V
      vanessa82Aug 19, 2025
      If your Atlantic Heater isn't heating or cooling enough, first ensure you're in COMFORT mode. Also, check that the heater is only heating one room by keeping the door closed. Remove anything that might be blocking the appliance. Adjust the thermostat if it's set too high for cooling or too low for heating by pressing the appropriate buttons. If there's no filter located under the appliance, contact After Sales or your installer. If the problem continues, contact After Sales and ask your installer to check the weather-dependent set-point parameters.
  • B
    Bruce EdwardsAug 21, 2025
    Why doesn't my Atlantic Panama 1000 Heater heat?
    • C
      Chelsea WarrenAug 21, 2025
      If your Atlantic Heater isn't heating, make sure the COMFORT mode is activated. Check that the circuit breakers or load-shedding device (if applicable) haven't cut off the heater's power. Also, verify the room's air temperature; if it's too high, the heater won't activate.
  • M
    Marcia BerryAug 25, 2025
    What to do if there is smoke or an unpleasant smell from my Atlantic Heater?
    • C
      Christopher HubbardAug 25, 2025
      If you notice smoke or an unpleasant smell coming from your Atlantic Heater, this could indicate a component failure, power surge, or electrical overload. Immediately turn off the power to the unit and contact After Sales service for assistance.
  • S
    Sarah WoodsAug 28, 2025
    Why does my Atlantic Panama 1000 Heater heat all the time?
    • J
      jeffrey58Aug 28, 2025
      If your Atlantic Heater is constantly heating, ensure it's not positioned in a drafty area and that the temperature settings haven't been inadvertently altered. There might also be a fluctuation in the electrical network. Try cutting off the heater's power supply (fuse, circuit breaker) for about 10 minutes, then turn it back on. If the problem persists frequently, have your power supply checked by your energy distributor.
  • G
    George MullinsAug 30, 2025
    What does it mean when the signal lamp lights up on my Atlantic Heater?
    • A
      Ariel HendersonAug 30, 2025
      If the signal lamp on your Atlantic Heater lights up, this indicates that you need to clean the filter located under the appliance, as well as the grid at the bottom front.
  • J
    Jacqueline RoseSep 2, 2025
    Why is my Atlantic Heater so noisy?
    • L
      Leslie HensleySep 3, 2025
      If your Atlantic Heater is noisy, the filter may be dirty, so clean the air filter. Also, remove any obstructions in front of the appliance. If the noise is due to water circulating, this is a normal part of the installation and not a fault. If the fan is always at maximum speed, ask your installer to adjust the weather-dependent setpoint parameters. If the noise persists, contact After Sales.
  • D
    David GriffinSep 5, 2025
    Why are there dirty marks on the wall around my Atlantic Panama 1000 Heater?
    • L
      Lisa ChaneySep 5, 2025
      If you see dirty marks on the wall around your Atlantic Heater, it's usually due to poor air quality. Ensure the room is properly ventilated, the air is clean, and avoid smoking indoors. These marks do not qualify for a warranty replacement.
  • L
    Laura YoungSep 9, 2025
    Why does the heating signal lamp appear on the screen when the Atlantic Heater is in Eco mode?
    • C
      Cheryl ThompsonSep 9, 2025
      This is normal. Your Atlantic Heater may heat to maintain the Eco temperature.
  • A
    alexander51Sep 12, 2025
    Why does my Atlantic Panama 1000 continue to heat when the window is open?
    • Y
      ywalkerSep 12, 2025
      There may be a slight delay between opening the window and the Atlantic Heater stopping heating. If the delay is too long, you can manually stop the appliance from heating.

Summary

Characteristics

Technical Characteristics of the Appliance

Detailed technical specifications for the Panama radiator models.

Operating Limits

Defines the minimum and maximum operating parameters for the appliance.

Warnings

General Safety Warnings

Crucial safety instructions to prevent injury and ensure proper use of the appliance.

Installation

Before Installing Your Appliance

Guidelines and rules for the initial placement and preparation of the appliance.

Locating Hydraulic and Electric Connections

Guidance on positioning the appliance for optimal connection of water and power supplies.

Fixing the Fixing Bar to the Wall

Instructions for marking and preparing the wall for the appliance's mounting bar.

Fixing the Appliance onto the Fixing Bar

Step-by-step guide on how to mount the appliance onto the wall-mounted fixing bar.

Electric Connections

Detailed instructions and wiring diagrams for connecting the appliance to the power supply.

Hydraulic Connections

Procedures for connecting the appliance to the heating system's water circuit.

Operation

Use

Energy Saving: Absence and Presence Detection

Automatic temperature adjustment based on room occupancy for energy savings.

Calibrating the Temperature

Temperature Calibration Process

Procedure to adjust the displayed temperature for accurate room readings.

Returning to Factory Settings

Troubleshooting

Common Problems and Solutions

A guide to identifying and resolving common issues with the appliance.

Atlantic Panama 1000 Specifications

General IconGeneral
Heating Power1000 W
Voltage230 V
Frequency50 Hz
Heating Area10-15 m²
Safety FeaturesOverheat Protection, Tip-over Switch
Weight3.5 kg
TypeConvection Heater
ThermostatAdjustable