8     6996 0223 70 
8.  It is not allowed to walk or stand on the unit or on its components. 
9.  Never block the outlet in case the pump is used as a vacuum pump. 
 
 
1.3  Safety precautions during installation 
All responsibility for any damage or injury resulting from neglecting these precautions, or 
non-observance  of  the  normal  caution  and  care  required  for  installation,  operation, 
maintenance  and  repair,  even  if  not  expressly  stated,  will  be  disclaimed  by  the 
manufacturer. 
 
1.  The  machine  must  only  be  lifted  using  suitable  lifting  equipment  in  accordance  with  the  applicable  safety 
regulations. Loose or pivoting parts must be securely fastened before lifting. It is strictly forbidden to dwell or stay 
in the risk zone under a lifted load. Lifting acceleration and deceleration must be kept within safe limits. Wear a 
safety helmet when working in the area of overhead or lifting equipment. 
2.  The unit is designed for indoor use. If the unit is installed outdoors, special precautions must be taken; consult 
Atlas Copco. 
3.  Place the machine where the ambient air is as cool and clean as possible. Never obstruct the cooling air inlet. 
Water handling capacity is limited. For operating in such applications, consult Atlas Copco. 
4.  Any blanking flanges, plugs, caps and desiccant bags must be removed before connecting the pipes. 
5.  All connections must be of correct size and suitable for working pressure and temperature. Never use frayed, 
damaged or worn hoses. Distribution pipes and connections must be of the correct size and suitable for the 
working pressure and temperature. 
6.  The aspirated air must be free of flammable fumes, vapors and particles, for example, paint solvents that can 
lead to internal fire or explosion. Follow the material safety. 
7.  Arrange the air intake so that loose clothing worn by people cannot be sucked in. 
8.  Ensure no external force exerted on the inlet and outlet connection. The connection pipes must be free of strain. 
No supports may be fixed to the canopy of the machine. 
9.  If remote control is installed, the machine must bear a clear sign stating: 
 
DANGER: This machine is remotely controlled and may start without warning. 
 
The operator has to make sure that the machine is stopped and that isolating switch is open and locked before 
any maintenance or repair. As a further safeguard, persons switching on remotely controlled machines shall take 
adequate precautions to ensure that there is no one checking or working on the machine. To this end, a suitable 
notice shall be affixed to the starting equipment. 
10. Air-cooled machines must be installed in such a way that an adequate flow of cooling air is available and that the 
exhausted air does not recirculate to the vacuum/over-pressure pump air inlet  of the vacuum relief valve or 
cooling air inlet. 
11. The  electrical  connections  must  correspond  to  the  applicable  codes.  The  machines  must  be  earthed  and 
protected against short circuits by fuses in all phases. A lockable power isolating switch must be installed near 
the vacuum/over-pressure pump. 
12. On machines with automatic start/stop system or if the automatic restart function after voltage failure is activated, 
a sign stating “This machine may start without warning” must be affixed near the instrument panel. 
13. In multiple vacuum/over-pressure pump systems, manual valves must be installed to isolate each pump. Non-
return valves (check valves) must not be relied upon for isolating multiple systems. 
14. Never remove or tamper with the safety devices, guards or insulation fitted on the machine. 
15. Piping or other parts with a temperature that exceeds 70°C (158°F) and which may be accidentally touched by 
personnel in normal operation must be guarded or insulated. Other high temperature piping must be clearly 
marked. 
16. If the ground is not leveled or can be subject to variable inclination, consult the manufacturer. 
17. Whenever air containing hazardous substances are sucked in (that is, biological or microbiological agents), use 
abatement systems placed upstream of the vacuum/over-pressure pump. 
18. Any pump placed in an application with inlet gas stream temperatures above the published maximum temperature 
should be approved by Atlas Copco prior to start-up.