Instruction Book
6996 0223 70 43
Technical data
8.1 Reference conditions and limitations
Reference conditions
Unit
Relative humidity
%
0
Air inlet temperature
°C
20
°F
68
Exhaust back pressure
mbar(g)
0
psi
0
Ambient barometric pressure
mbar(a)
1013
psi
14.7
Limitations
Unit
Minimum ambient temperature
°C
0
°F
32
Maximum ambient temperature
°C
40
°F
104
Minimum allowable inlet temperature
°C
0
°F
32
Maximum allowable inlet temperature
°C
40
°F
104
Maximum (absolute) inlet pressure
mbar(a)
1050
psi
15.22
Maximum outlet pressure mbar(a) (vacuum pump)
mbar(a)
1013
psi
14.7
Maximum outlet pressure mbar(g) (over-pressure pump)
bar(g)
2.5
psi
36.3