If it is judged that the electric motor is defect or in need of service, the complete motor unit should be re-
turned to Atlas Copco Industrial Technique AB for exchange.
Motors which have been opened by anyone else than Atlas Copco Industrial Technique AB will not be ser-
viced.
Overhaul and preventive maintenance is recommended at regular intervals once per year, after maximum
6.000.000 pulses, depending on which occurs first. More frequent overhaul may be needed if the machine
is used in heavy-duty operations. If the machine is not working properly, it should immediately be taken
away for inspection.
When dismantling the tool always use the specially designed service tool(s) recommended in the Spare
Parts section on ServAid - https://servaid.atlascopco.com.
Lubrication Instructions
Lubricating Guide
Brand General purpose
Almagard LE3752
Oil Filling and Changing Instruction for Pulse Unit
Required equipment for oil filling and oil changing:
Atlas Copco Pulse unit oil.
Atlas Copco Pulse unit Oil Filling Kit.
For ordering number for Spare Parts, see https://servaid.atlascopco.com.
Oil Filling Equipment Kit
2 x Adapter M3
2 x Adapter M4
4 x Hose length 540 mm
2 x Hose length 50 mm
1 x Hose length 120 mm
1 x Syringe 50 ml
1 x Syringe 1 ml
4 x Plug
5 x Connection
2 x Connection
2 x Can
2 x Cover
1. Place the Pulse unit in a vise at an angle so that the outlet whole is at the highest point.
2. Remove the screw covering the inlet opening. Make sure that the o-ring is on the screw and not left
in the Pulse unit. Attach the filling hose by hand, with the hose connector end to the Pulse unit.
3. Fill the large syringe with oil to maximum capacity from the oil can.
Always use new Atlas Copco Pulse unit oil.
4. Remove the stop plug from the filling hose and then attach the syringe to the hose.
5. Remove the screw covering the outlet opening of the Pulse unit. Make sure that the o-ring is on the
screw and not left in the Pulse unit. Attach the return hose to the Pulse unit.
6. Remove the stop plug from the return hose and then attach it to the oil can.
7. Start filling oil into the Pulse unit from the large syringe. When filling oil into the Pulse unit, there will
be air bubbles exiting.