Type V Hz Approval Setting F21 (A) Setting Q15 (A)
GA 15 575 60 cULus / cCSAus 14.5 0.5
GA 18 230 50 IEC 43.5 1.1
GA 18 230 60 IEC 44.3 0.7
GA 18 380 60 IEC 25.9 0.4
GA 18 400 50 IEC 25.2 0.6
GA 18 460 60 IEC 22.1 0.4
GA 18 200 60 cULus / cCSAus 49.6 0.7
GA 18 230 60 cULus / cCSAus 44.3 0.7
GA 18 460 60 cULus / cCSAus 22.1 0.5
GA 18 575 60 cULus / cCSAus 17.5 0.5
GA 22 230 50 IEC 50.4 2.5
GA 22 230 60 IEC 51.9 1.2
GA 22 380 60 IEC 30.5 0.7
GA 22 400 50 IEC 29 1.3
GA 22 460 60 IEC 25.9 0.7
GA 22 200 60 cULus / cCSAus 58.8 1.3
GA 22 230 60 cULus / cCSAus 51.9 1.2
GA 22 460 60 cULus / cCSAus 25.9 0.7
GA 22 575 60 cULus / cCSAus 20.6 0.7
GA 26 230 50 IEC 61 2.5
GA 26 230 60 IEC 61 2.9
GA 26 380 60 IEC 36.6 1.7
GA 26 400 50 IEC 35.1 1.3
GA 26 460 60 IEC 30.5 1.7
GA 26 200 60 cULus / cCSAus 68.7 2.9
GA 26 230 60 cULus / cCSAus 61 2.9
GA 26 460 60 cULus / cCSAus 30.5 1.7
GA 26 575 60 cULus / cCSAus 24.4 1.7
14.4 Dryer switches
General
The regulating and safety devices are factory-adjusted to give optimum performance of the dryer.
Do not alter the setting of any of the devices.
Instruction book
152 2920 7140 90