B. Unscrew the oil cooler connector on casing.
C. Unscrew the oil cooler connector on tube.
3. Place the motor in vertical orientation so that motor shaft facing upwards.
4. Make sure that the turbine support is on a 3 mm (0.11 inch) thickness spacer.
5. Tighten the screw to 2 Nm torque. Apply LOCTITE 243.
12/2021 - ©Atlas CopcoPage 616996022430_C
Installation