Compressor type GX7 GX11 GX7 GX11 GX7 GX11
Nominal motor power
rating
kW 7.5 11 7.5 11 7.5 11
Nominal motor power
rating
hp 10 15 10 15 10 15
Dryer power
consumption at full
load, Full Feature
units
kW 0.36 0.36 0.36 0.36 0.36 0.36
Dryer power
consumption at full
load, Full Feature
units
hp 0.48 0.48 0.48 0.48 0.48 0.48
Oil capacity l 3 3.2 3 3.2 3 3.2
Oil capacity US gal 0.8 0.84 0.8 0.84 0.8 0.84
Oil capacity Imp gal 0.65 0.7 0.65 0.7 0.65 0.7
Oil capacity cu.ft 0.1 0.11 0.1 0.11 0.1 0.11
Sound pressure level
(according to ISO
2151 (2004))
dB(A) 65 67 65 67 65 67
60 Hz 100-125 psi (under reference conditions)
Compressor type GX7 GX11 GX7 GX11
Frequency Hz 60 60 60 60
Maximum (unloading) pressure,
Pack
bar(e) 7.4 7.4 9.1 9.1
Maximum (unloading) pressure,
Pack
psig 107 107 132 132
Maximum (unloading) pressure,
Full-Feature
bar(e) 7.15 7.15 8.85 8.85
Maximum (unloading) pressure,
Full-Feature
psig 103.7 103.7 128 128
Nominal working pressure bar(e) 6.9 6.9 8.6 8.6
Nominal working pressure psig 100 100 125 125
Set-point, thermostatic valve ˚C 75 75 75 75
Set-point, thermostatic valve ˚F 167 167 167 167
Temperature of air leaving outlet
valve (approx.), Pack
•
Tank-mounted
˚C 38 43 38 43
•
Tank-mounted
˚F 100 109 100 109
•
Floor-mounted
˚C 60 66 60 66
•
Floor-mounted
˚F 140 151 140 151
Temperature of air leaving outlet
valve (approx.), Full-Feature
˚C 23 25 23 25
Temperature of air leaving outlet
valve (approx.), Full-Feature
˚F 73 77 73 77
Instruction book