2920 7090 00 49
Instruction book
5 Maintenance
5.1 Petrol engine maintenance
Consult the engine "Owner's manual".
5.2 Preventive maintenance schedule
The schedule contains a summary of the maintenance instructions. Read the respective
section before taking maintenance measures.
When servicing, replace all disengaged packing components, e.g. gaskets, O-rings,
washers. The "longer interval" checks must also include the "shorter interval" checks.
Period Running Hours Operation Consult
Section
See notes
below table
Preventive
maintenance kit
Daily Drain
condensate
from air
receiver or
pulsation
damper.
Air receiver
instructions
- -
6-monthly Test safety
valve
Safety valve
Relief valve
1
6-monthly Inspect air filter Air filter 2/3 2
Yearly 500 On LF 10,
replace air filter
Air filter 2
Yearly 600 On LF 5 and
LF 7, replace
air filter
Air filter 2
Yearly 800 On LF 1 and
LF 3, replace
air filter
Air filter 2
Yearly 2000 Change blow
off silencer, If
provided
- - 2
7500 Replace valve
discs.
Valves - 1
Notes:
1. Wear gloves and safety glasses.
2. For normal operation in clean surroundings. More frequently when operating in a dusty
environment.
3. In a dusty environment, a heavy-duty filter (available as an option) is essential.
Preventive maintenance schedule Full Feature units
Only applicable on the refrigerant dryer.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco LF 2 and is the answer not in the manual?

Atlas Copco LF 2 Specifications

General IconGeneral
BrandAtlas Copco
ModelLF 2
CategoryCompressor
LanguageEnglish

Related product manuals