Condition Fault Remedy
Insufficient air pressure
Air leak Check and correct as
necessary
Air filter choked Replace filter
Air pressure switch incorrectly
set
Adjust switch
Air consumption exceeds
maximum output of compressor
Check equipment connected
Damaged valve Inspect valves and replace
parts where necessary
Unloader malfunctioning Inspect and replace parts
where necessary
Solenoid valve out of order Remove and check. Replace if
necessary
Unit does not speed up
Voltage drop at motor terminals Consult power supplier. Use
correct size of cable
Unloader malfunctioning Inspect and replace parts
where necessary
Solenoid valve out of order Remove and check. Replace if
necessary
Blow-off silencer choked Replace
Air receiver pressure rises above
maximum and causes safety valve to
blow
Air pressure switch or pilot
valve incorrectly set or out of
order
Check. Replace switch or valve,
if necessary
Solenoid valve defective Remove and check. Replace if
necessary
Unloader malfunctioning Inspect and replace parts
where necessary
Blow-off silencer choked Replace
Receiver does not hold pressure
Check valve leaks Check for broken valve and
springs
Air leaks Check and correct as
necessary
Too frequent starting/too short
operating periods
Air pressure switch or pilot
valve incorrectly set
Increase pressure difference
Check valve leaks Check for broken valve and
springs
Unit does not start Electrical failure Have electrical system
checked. Check fuses and line
terminals for tightness