Instruction book
Atlas Copco Stationary Air Compressors
LE2, -3, -5, -7, -10, -15, -20
LT2, -3, -5, -7, -10 (50 Hz)
LT15/60, -15-30, -15, -20, -20-30
LF2, -3, -5, -7, -10
Instruction book
Copyright 2004, Atlas Copco Airpower n.v., Antwerp, Belgium.
Any unauthorized use or copying of the contents or any part thereof is prohibited. This applies in
particular to trademarks, model denominations, part numbers and drawings.
This instruction book meets the requirements for instructions specified by the machinery directive
98/37/EC and is valid for CE as well as non-CE labelled machines.
No. 2920 1585 00
Registration code: APC L / 38 / 985
2004-07
2920 1585 00 - 1 -

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco LT10 and is the answer not in the manual?

Atlas Copco LT10 Specifications

General IconGeneral
TypePiston
Operating pressure max10 bar
FAD0.10 m³/min
Free Air Delivery0.10 m³/min
Voltage230 V
Phase1

Summary

Leading Particulars

General Description

Describes the types, stages, and cylinders of Atlas Copco compressors.

Installation and Handling

Electrical Connections

Outlines requirements for connecting the compressor's electrical system.

Settings of Overload Relay, Fuses, and Cable Size

Specifies settings for protection devices and cable sizing.

Operating Instructions

Initial Start-up

Guides the first-time setup and initial operation of the compressor.

Starting

Instructions on how to safely start the compressor.

Stopping

Procedures for safely shutting down the compressor.

Maintenance

Preventive Maintenance Schedule of the Compressor

Outlines regular checks and part replacements.

Servicing and Adjustment Procedures

Adjustment of MDR4S Pressure Switch

How to adjust the pressure switch for stopping/starting.

Adjustment of MDR3 Pressure Switch

How to adjust the pressure switch for stopping/starting.

Problem Solving

Principal Data