- 59 -
60 Hz
Performance class (acc.ISO 8528-5:1993) G2
Single step load acceptance (0-PRP) 70%
78.4 kW
Frequency droop isochronous
Fuel consumption at 0% load 6.50 kg/h
Fuel consumption at 50% load 30.84 kg/h
Fuel consumption at 75% load 43 kg/h
Fuel consumption at full load (100%) 59.26 kg/h
Specific fuel consumption at full load (100%) 0.224 kg/kWh
Fuel autonomy at full load 24.4 h
Max. oil consumption at full load -
Maximum sound power level (LPA) measured according to Atlas copco spec.
9822087700
74 dB(A)
Useful capacity of fuel tank 430 gal
Single step load capability (O-PRP) 100%
264 kW
Application data Mode of operation
PRP
Site land use
Operation single/parallel
Start-up and control mode manual/automatic
Start-up time unspecified
Mobility/Config. acc. to ISO 8528-1:1993 transportable/D
mobile/E
Mounting fully resilient
Climatic exposure open air
Degree of protection (Cubicle) IP 54
Status of neutral earthed
Alternator Standard
IEC 60034
ISO 8528-3
Make LEROY SOMER
Model LSA 46.2 L9
Rated output, class H temperature rise 343 kVA
rating type acc. ISO 8528-3 “BR” 125/40°C
Degree of protection IP 23
Insulation stator class H
Insulation rotor class H
Number of wires 12
Engine Standard
ISO 3046
ISO 8528-2
Technical specifications for QAS 330 JD T4i