- 33 -
Replace fuel (primary)filter(s) (5) xxx
Inspect/Adjust fan/alternator belt x x x x x
Replace fan/alternator belt xx
Measure alternator insulation resistance (11) xx
Test Earth Leakage Relay (12) xxx
Check emergency stop (12) xxx
Clean radiator (1) xxx
Check for obstructions on crankcase breather system / filter and
hoses
x
Drain condensate and water from spillage-free frame or catch
basin (8)
xxx
Check for leaks in engine-, air-, oil-, or fuel system xxx
Inspect/Replace hoses and clamps xxx
Check electrical system cables for wear xx
Check/Test glow plugs - grid heater xx
Check torque on critical bolt connections xx
Check electrolyte level and terminals of battery (10) x x x
Analyse coolant (4) (7) xxx
Check external fuel connection (option) xx
Grease locks and hinges xxx
Check rubber flexibles (9) xx
Drain/Clean fuel tank water and sediment (1) (13) xxx
Adjust engine inlet and outlet valves (2) x x x
Check fuel injectors (2) x
Maintenance schedule Daily
50 hrs
after initial
start-up
Every 250
hours
Every 500
hours
Every 1000
hours
Yearly
Service pak
---
TBA* TBA*
-