- 92 -
Capacity of fuel tank 55 l 55 l 55 l 55 l
Single step load capability 16.8 kW 18.4 kW
100% 100% 100% 100%
Application data Mode of operation PRP PRP PRP PRP
Site land use land use land use land use
Operation single single single single
Start-up and control mode manual/automatic manual/automatic manual/automatic manual/automatic
Start-up time unspecified unspecified unspecified unspecified
Mobility/Config. acc. to ISO 8528-1:1993 transportable/D transportable/D transportable/D transportable/D
(optional) mobile/E mobile/E mobile/E mobile/E
Mounting fully resilient fully resilient fully resilient fully resilient
Climatic exposure open air open air open air open air
Status of neutral (TT or TN) (optional) earthed earthed earthed earthed
Alternator 4) Standard IEC34-1 IEC34-1 IEC34-1 IEC34-1
ISO 8528-3 ISO 8528-3 ISO 8528-3 ISO 8528-3
Make MeccAlte MeccAlte MeccAlte MeccAlte
Model ECP28-M/4 ECP28-M/4 ECP28-2L/4A ECP28-2L/4A
Rated output, class H temp. rise - 3ph 21 kVA 23 kVA 17 kVA 25 kVA
rating type acc. ISO 8528-3 125/40°C 125/40°C 125/40°C 125/40°C
Degree of protection (IP index acc. NF EN 60-529) IP 23 IP 23 IP 23 IP 23
Insulation stator class HHHH
Insulation rotor class HHHH
Number of wires 12 12 12 12
Engine 4) Standard ISO 3046 ISO 3046 ISO 3046 ISO 3046
ISO 8528-2 ISO 8528-2 ISO 8528-2 ISO 8528-2
Type KUBOTA V2403M-BG V2403M-BG V2403M-BG V2403M-BG
Rated net output (PRP) 22.1 kW 22.1 kW 22.1 kW 22.1 kW
rating type acc. ISO 3046-7 ICXN ICXN ICXN ICXN
Coolant coolant coolant coolant coolant
Combustion system indirect injection indirect injection indirect injection indirect injection
Aspiration natural aspirated natural aspirated natural aspirated natural aspirated
Number of cylinders 4444