4.2.8 Stopping the engine
Follow the instructions below to switch the engine off
correctly:
1. Lower the mast. See section 4.2.7.
2. Disconnect the electrical appliances connected to
the socket (1).
3. Push the STOP button on the Lc1003™ module
(2) to go into cool down.
4. After cool down, which takes approx. 30 sec., put
the starter switch S20 in position O (OFF) (3).
5. Place all the automatic switches in their OFF
position (4).
6. If the optional External power input (230 VAC) is
installed, switch S10 to O (OFF) (5). See also
“External power input (230 VAC), with battery
charger” on page 66.
Q2 Q3 Q4 Q5Q1
40A/30mA
Q6
X1
X2
0
1
P8
GE
ON
Q1 Q2 Q3 Q4 Q5 Q6
4
5
1
2
3
Should an emergency arise, it is also
possible to stop the machine by
pressing the EMERGENCY 'STOP'
button (6). If the light tower has
been stopped in this way, the
emergency stop button must be
released by rotating it clockwise, for
next operation.