EasyManua.ls Logo

Atlas Copco QLT H50 Kd ESF - Page 73

Atlas Copco QLT H50 Kd ESF
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 73 -
Design Data Alternator 4) Standard IEC34-1
ISO 8528-3
Make MECCALTE
Model LT3N-160/4
Rated output, class H temperature rise 8 kVA
Rating type acc. ISO 8528-3 "BR" 125/40°C
Degree of protection (IP index acc. NF EN 60-529) IP 21
Insulation stator class H
Insulation rotor class H
Number of wires 4
Electrical power circuit Circuit-breaker 1ph:
Number of poles 2
Thermal release (lt) 40 A
Fault current protection, residual current release, Idn 0.03 A
Circuit-breaker 1ph:
Number of poles 1
Thermal release (lt) 16 A
Magnetic release (lm) 5 x In
Circuit-breaker 1ph:
Number of poles 1
Thermal release (lt) 10 A
Magnetic release (lm) 5 x In
Lights Number of lights 4
Type of lights Metal Halide
Light output 1000 W
Lamps type 9.5 A
Tower height 8.6 m

Table of Contents

Related product manuals