- 104 -
1)
Free Air Delivery (volume flow rate) is measured according to ISO 1217 ed.4 2009 annex D
Tolerance:
+/- 5% 25 l/s (53 cfm) < FAD < 250 l/s (530 cfm)
+/- 4% 250 l/s (530 cfm) < FAD
2)
XAS 67 - XAS 130: compressor and generator
Typical oil content of compressed air mg/m
3
< 5< 5< 5< 5< 5< 5
oz/1000 cu.ft < 0.005 < 0.005 < 0.005 < 0.005 < 0.005 < 0.005
Engine oil consumption (maximum) g/h 17 20 37 17 37 37
oz/h 0.6 0.7 1.3 0.6 1.3 1.3
Compressed air temperature at
outlet valves
without
aftercooler
°C 89 94 90 89 90 90
°F 192 201 194 192 194 194
with aftercooler°C 303030303030
°F 86 86 86 86 86 86
Noise level
- Sound pressure level (Lp), measured according to
ISO 2151 under free field conditions at 7 m distance
dB(A) 707072707272
- Sound power level (Lw) complies with
2000/14/EC
dB(A) 989898989898
Designation
XAS 67 -
XAS 130
XAS 67 -
XAS 130
(Generator)
XATS 67 -
XATS 125
XAS 77 -
XAS 150
XAS 97 -
XAS 185
XAS 97 -
XAS 185
(Generator)