1310 3011 65 5
21 Protect the engine, alternator, air intake filter, electrical
and regulating components, etc. to prevent moisture
ingress, e.g. when steam-cleaning.
22 When performing any operation involving heat, flames
or sparks on a machine, the surrounding components
shall first be screened with non-flammable material.
23 Never use a light source with open flame for inspecting
the interior of a machine, pressure vessel, etc.
24 On portable units, support the drawbar and axle(s)
securely if working underneath the units or when
removing a wheel. Do not rely on jacks.
25 Prior to stripping a compressor, engine or other
machine or undertaking major overhaul on it, prevent
all movable parts with a mass exceeding 15 kg (30 lbs)
from rolling over or moving.
26 When repair has been completed, make sure that no
tools, loose parts or rags are left in, or on, the
machine, the prime mover or the driving gear. The
machine shall be barred several revolutions to ensure
that there is no mechanical interference within the
machine or driver.
1.3 Safety during use and operation
To lift a unit, all loose or pivoting parts, e.g. doors shall first
be securely fastened. Do not attach cables, chains or
ropes directly to the lifting eye; apply a crane hook or lifting
shackle meeting local safety rules.
Helicopter lifting using the lifting eye is forbidden.
It is strictly forbidden to dwell or stay in the risk zone under
a lifted load. Never lift the unit over people or residential
areas.
Lifting acceleration and retardation shall be kept within safe
limits.
1 Before towing the unit:
- ascertain that the pressure vessel(s) is (are)
depressurized,
- check the drawbar, the brake system and the towing
eye. Also check the coupling of the towing vehicle,
- check that the pivot wheel or stand leg is safely
locked in the raised position,
- ascertain that the towing eye can swivel freely on
the hook,
- check that the wheels are secure and that the tires
are in good condition and inflated correctly,
- connect the signal cable, check all lights and
connect the pneumatic brake couplers,
- attach the safety break-away cable to the
towing vehicle,
- remove wheel chocks, if applied, and disengage the
parking brake.
- Apply safety chains to tow vehicle.
2 If the unit is to be backed up by the towing vehicle,
disengage the overrun brake mechanism (if equipped).
3 Never exceed the maximum towing speed of the unit.
4 Place the unit on level ground and chock the wheels before
disconnecting the unit from the towing vehicle. Unclip the
safety break-away cable
5 When the unit has to operate in a fire-hazardous
environment, each engine exhaust has to be provided with
a spark arrestor to trap incendiary sparks.
6 The exhaust contains carbon monoxide which is a lethal
gas. When the unit is used in a confined space, conduct
the engine exhaust to the outside atmosphere by a pipe of
sufficient diameter (min. 4 inches); do this in such a way
that no extra back pressure is created for the engine. If
necessary, install an extractor.
7 When operating in a dust-laden atmosphere, place the unit
so that dust is not carried towards it by the wind. Operation
in clean surroundings considerably extends the intervals for
cleaning the air intake filters and the cores of the coolers.
8 Locate the unit away from walls. Take all precautions to
ensure that hot air exhausted from the engine and driven
machine cooling systems cannot be recirculated. If such
hot air is taken in by the engine or driven machine cooling
fan, this may cause overheating of the unit; if taken in for
combustion, the engine power will be reduced.
9 No external force may be exerted on the air outlet valves,
e.g. by pulling on hoses or by installing auxiliary equipment
directly to a valve, e.g. a water separator, a lubricator, etc.
10 Distribution pipework and air hoses must be of correct size
and suitable for the working pressure.
Never use frayed, damaged or deteriorated hoses.
Replace hoses and flexibles of which the lifetime expired.
Use only the correct type and size of hose end fittings and
connections.
A hose connected to a 2 inch (50 mm) valve must be
provided with a safety wire (8 mm) fixed to the hose for
effective pressures as from 10 bar (145 psi) up, although it
is recommended to apply such safeguard already from 4
bar (60 psi) up. The safety wire ends have to be attached,
one to the eye provided next to the compressor air outlet
valve, the other one to a point near to the air inlet of the
applied equipment.
Finally a wire mesh hose can be fixed over the hose ends
to dampen the blast in case a connection starts leaking or
should become undone.
Close the compressor air outlet valve before connecting or
disconnecting a hose. Ascertain that a hose is fully
depressurized before disconnecting it.
When blowing through a hose or air line, ensure that the
open end is held securely. A free end will whip and may
cause injury.
Never play with compressed air. Never apply it to your skin
or direct an air stream at people. Never use it to clean dirt
from your clothes. When using it to clean down equipment,
do so with extreme caution and use eye protection.
11 Never move a unit when external lines or hoses are
connected to the outlet valves, to avoid damage to valves
and/or manifold and hoses.
12 Never refill fuel while the unit is running. Keep fuel away
from hot parts such as air outlet pipes or the engine
exhaust. Do not smoke when fueling. When fueling from
an automatic pump, a ground cable should be connected to
the unit to discharge static electricity. Never spill nor leave
oil, fuel, coolant or cleansing agent in or around the unit.