Press the key ”Program” to program the new value or the key “Cancel” to cancel the modification
operation (the original value will be retained).
Modifying the shut-down warning setting for the oil pressure
The vertical arrow on the screen above indicates to use the scroll key to show the related warning
value:
Oil 2.5 bar
Programmable settings
Shutd Warn Minimum 1.3 bar
Menu Modify
F1 F2 F3
After pressing the key “Modify” the value of the parameter starts blinking and the functions of the
keys (F1, F2 and F3) change into “Program”, “Limits“ and “Cancel” respectively.
Modify the value by means of scroll keys (1).
Press the key ”Program” to program the new value or the key “Cancel” to cancel the modification
operation (the original value will be retained).
Delay at signal
The vertical arrow on the screen above indicates to use the scroll key to show the programmed “Delay
at signal”:
Oil
Programmable settings
Delay at Signal 15 sec
Menu Modify
F1 F2 F3
If it should be necessary to modify the nominal setting, consult the Atlas Copco Customer Centre.
Modify the value by means of scroll keys (1).
Press the key ”Program” to program the new value or the key “Cancel” to cancel the modification
operation (the original value will be retained).
The vertical arrow on the screen above indicates to use the scroll key to show the programmed “Delay
at start”. If it should be necessary to modify the nominal setting, consult the Atlas Copco Customer
Centre.
The regulator will not accept new values beyond the limitations.
It is possible to check the limitations which are valid for the parameter to be modified by
selecting Limits.
Instruction book
62 2920 1815 04