Term Explanation
Unloading/
Loading pressure
The regulator does not accept illogical settings, e.g. if the unloading pressure is
programmed at 7.5 bar(e), the maximum limit for the loading pressure changes into 7.4
bar(e). The recommended minimum pressure difference between loading and unloading
is 1 bar.
Unloading/
Loading pressure
The regulator does not accept illogical settings, e.g. if the unloading pressure is
programmed at 109 psi, the maximum limit for the loading pressure changes into 108
psi. The recommended minimum pressure difference between loading and unloading is
14.5 psi.
Delay at starting Is the time interval within which the oil pressure must be built up.
Delay at signal Is the period during which the signal is ignored.
Instruction book
74 2920 1815 04