Operation with permanent glowing
It is possible to operate the boiler with permanent glowing, it means the fire can be kept during the
whole night without firing up every day. In the boiler the burning process can continue for more than 12
hours, therefore it is possible after a filling up of the wood and after switching on the ventilator to reach
in a short time the full power output of the boiler again. When operating the boiler with permanent glo-
wing, the water temperature must remain at 80 – 90 °C.
Cleaning of the boiler
The cleaning of the boiler should be performed regularly and properly in a time interval of 3 – 5 days,
because the ash sediments in the fuel container reduce together with tars and condensates the life and
power output of the boiler and isolate the heating surface. In case of great volume of ash in the fuel con-
tainer there is no sufficient space for burning, the holder of the ceramic nozzle and also the whole boiler
can be damaged.
Steps: First switch off the ventilator. In case, the boiler is equipped with an exhaust ventilator, this ven-
tilator should run. Open the filling door /2/ and sweep the ash through the hole into the lower chamber.
The time interval of the cleaning depends on the wood quality (moisture) and heating intensity, chimney
draught (flue) and on other conditions. We recommend to clean the boiler once a week. Do not pull out
the fireclay shaped pieces during the cleaning process. For the boiler types DC 20GS, DC 25GS,
DC 32GS, DC40GS we offer an additional ash pan, which can be pushed in the lower round space
during the cleaning procedure.
7
CERAMIC ASH COLLECTOR
REAR BOILER SPACE
CERAMICS
ASH
MAX. ASH VOLUME!
NOTICE:
The regular and proper cleaning is important to ensure the constant power output and long
durability of the boiler. In case of unsufficient cleaning the boiler can be damaged the guarantee
becomes extinct.