Contents
1. Intended use 3
2. Technical specifications
3
Control panel for boilers with ventilator 4
Control panel for boiler DC15E 4
Advantages of boilers 5
3. Technical data
6
Boiler drawings key 7
Technical data 7
Drawings of boilers 8
Cut away view - DC15E 9
Cut away view – DC70S 9
Extraction ventilator schematics 10
4. Type and seating of shaped pieces into combustion area 1
0
5. Boiler accessories 1
2
6. Fuel 1
2
Basic wood burning data 12
7. Boiler bases 1
3
8. Environment type and boiler placement in a boiler room 1
4
9. Chimney 1
4
10. Flue-gas duct 1
4
11. Fire prevention during installation and use of heating appliances 1
5
12. Connecting boilers to the electric network 1
6
13. Wiring diagram of electromechanical regulation with extraction ventilátor,
type UCJ 4C52 (DC18S – DC40SE) and with pressure ventilátor (DC80, DC7OS, DC22SX – DC40SX) 1
6
14. Wiring diagram of electromechanical regulation with an UCJ 4C52 ( DC5OSE) type extraction ventilator 1
7
15. Wiring diagram of electromechanical regulation of the DC15E type boiler 1
7
16. Wiring diagram for DC75SE - electromechanical regulation with an UCJ 4C52 type extraction ventilator 1
8
17. Obligatory ČSN EN standards dealing with boiler designing and boiler assembly 1
8
18. Choice and connection method of control and heating elements 1
9
19. Boiler corrosion protection 2
0
20. Specified boiler connection with Laddomat 21 2
0
21. Specified boiler connection with thermoregulation 2
1
22. Boiler connection with equilizing tank 21
23. Recommended wiring diagram with Laddomat 21 and accumulators 2
2
24. Laddomat 21 2
3
25. Thermoregulatory valve ESBE 2
3
26. Operating a system with accumulation tanks 2
4
The standard ATMOS accumulation tanks provided 24
Tank insulation 24
Advantages 24
27. Connection of overheat protecting cooling loop with a safety valve Honeywell TS 130 - 3/4 A
or WATTS STS20 2
5
28. Operating instructions 2
5
Preparing boilers for operation 25
Ignition and operation 26
Output regulation - electromechanical 26
Draught regulator - HONEYWELL Braukmann FR 124 – Assembly instructions 27
29. Boiler output and combustion setting 2
8
For boilers with DC18S – DC75SE draught ventilator 28
Boiler with compressive ventilator DC70S 28
Setting the servo-drive controlled valve with in-built spring for boilers DC50SE 29
30. Fuel refill 2
9
31. Steady heat operation 2
9
32. Boiler cleaning 3
0
Ceramic ash areas 31
33. Heating system maintenance - including boilers 3
2
34. Use and inspections 3
2
35. Possible failures and troubleshooting 3
2
36. Spares 3
3
Heatproof shaped piece (nozzle) replacement 34
Door sealing cord replacement 34
Adjusting the door hinges and locks 34
37. Environmental protection 3
5
Disposal of the boiler after expiration of its service life 35
GUARANTEE CONDITIONS 36
BOILER INSTALLATION REPORT 37
ANNUAL INSPECTIONS RECORDS 38
RECORDS OF GUARANTEE PERIOD AND POST-GUARANTEE PERIOD REPAIRS 39

Table of Contents

Questions and Answers

  • K
    Kyle BrownAug 8, 2025
    Why is my Atmos Boiler not reaching the required temperature?
    • A
      Amanda HallAug 8, 2025
      If your Atmos Boiler isn't reaching the required output temperatures, several factors could be responsible. Ensure there's enough water in the system by refilling it. The pump output might be excessive, so adjust the pump's switching and flow rate. Low-quality fuel, such as firewood with high moisture content or oversized logs, can also cause this issue; use dry firewood and split logs into halves. Finally, a leaking ignition valve may be the culprit, requiring repair.
  • K
    Karen AndersonAug 14, 2025
    What to do if the ventilator of my Atmos DC40SX does not turn?
    • T
      thomasamyAug 14, 2025
      If the ventilator of your Atmos Boiler isn't turning, first check if the boiler overheated, causing the safety thermostat fuse to trip; if so, press the thermostat push-button (using a pencil). A clogged rotating wheel can also prevent the ventilator from turning, so clean the ventilator, including the ducting, from tar and sediments. Other potential causes include a defective capacitor or motor, requiring replacement, or a bad contact in the plug of the motor cable lead, which should be checked.
  • M
    morrisrobertAug 21, 2025
    How to fix leaking doors on my Atmos DC40SX?
    • C
      Cynthia NormanAug 21, 2025
      If the doors of your Atmos Boiler are leaking, it could be due to a defective fibreglass cord, which needs replacement. Another cause might be a clogged nozzle; in this case, adjust the door hinges. Insufficient chimney draught can also contribute to this issue; avoid burning small-particle wood, sawdust, and bark.
  • J
    Jacob FosterAug 26, 2025
    What to do if the “mains” indicator is not lit up on my Atmos Boiler?
    • H
      Holly JimenezAug 26, 2025
      If the “mains” indicator on your Atmos Boiler is not lit, check for voltage in the network and ensure the plug is correctly inserted into the electrical socket. If these are fine, the power supply switch or electric cord may be defective and require replacement.
  • N
    Nathan MartinSep 1, 2025
    What causes Atmos DC40SX to not reach required outputs?
    • J
      Jasmine HarrisSep 1, 2025
      If your Atmos Boiler isn't reaching its required outputs and pre-set water temperatures, several issues might be responsible. Insufficient chimney draught can be a cause, suggesting a new chimney or unsuitable connection. Excessive chimney draught can also be a factor; in this case, place a throttle valve (draught limiter) in the flue-gas duct. Bent blades of the draught ventilator can reduce output; straighten the blades to a 90° angle. Other potential reasons include ignition being too long or the boiler being operated with the ignition flap open, requiring replacement, an insufficiently cleaned boiler, which needs cleaning, or a clogged combustion-air inlet to the loading chamber, which also requires cleaning.

Summary

Technical Specifications

Advantages of ATMOS Boilers

Detailed Technical Data

Extraction Ventilator Schematics

Fuel Specifications and Burning Data

Boiler Room Environment and Placement

Chimney and Flue-Gas Duct Requirements

Fire Prevention and Safety Distances

Safe Distances for Installation

Specifies minimum distances from building materials for safety.

Electrical Connection and Wiring Diagrams

Electromechanical Regulation with Extraction;Pressure Ventilator

Wiring diagram for electromechanical regulation with ventilators.

DC50 SE Extraction Ventilator Regulation Wiring

Wiring diagram for DC50SE boiler regulation.

DC15 E Boiler Regulation Wiring

Wiring diagram for the DC15E boiler's electromechanical regulation.

DC75 SE Extraction Ventilator Regulation Wiring

Wiring diagram for DC75SE boiler regulation.

Obligatory Standards for Boiler Installation

Control and Heating Element Selection

Boiler Corrosion Protection Methods

Boiler Connection Diagrams

Connection with Laddomat 21

Diagram showing boiler connection with Laddomat 21.

Connection with Thermoregulation

Diagram showing boiler connection with thermoregulation.

Wiring Diagram for Accumulation Tanks

Key Component Descriptions

Operating with Accumulation Tanks

Overheat Protection System

Boiler Operating Instructions

Ignition and Basic Operation

Procedures for igniting and operating the boiler.

Electromechanical Output Regulation

How to regulate the boiler's output using electromechanical means.

Draught Regulator FR 124

Boiler Output and Combustion Tuning

Servo-Drive Valve Adjustment for DC50 SE

Fuel Refill Procedure

Steady Heat Operation Mode

Boiler Cleaning Procedures

Operator Usage and Inspection Guidelines

Troubleshooting Common Failures

Spare Parts Identification

Component Replacement Procedures

Boiler Guarantee Conditions