3. Technical data
ATMOS boiler type
DC15E
DC18S DC22S
DC22SX
DC25S
DC30SX
DC32S
DC30SE
DC40SX
DC20GS
DC25GS
DC32GS
DC40GS DC40SE DC50S DC50SE
DC70S
DC80
DC75SE
Boiler output kW
10-14,9
14-20 15-22
15-22
17-25
21-30
24-35
28-40
14-20
17-25
24-32
28-40 28-40 35-48 35-49 49-70 52-75
Heat-up area m
2
1,8
1,8 2,1
1,9
2,3
2,3
2,9
2,9
1,9
2,7
2,9
3,2 3,5 3,8 4,2 5 5,2
Fuel duct volume dm
2
66
66 100
66
100
100
140
140
87 130 170 190 180 252 180 345
Feeding inlet dimensions mm
450x260
450x260 450x260
450x260
450x260
450x260
450x260
450x260
450x260 450x260 450x260 450x260 450x260 450x260 450x260 450x315
Specified chimney
draught
Pa
18
20 23
23
23
23
24
25
20 23/24 25 25 25 25 30 30
Max. water overheating kPa
250
250 250
250
250
250
250
250
250 250 250 250 250 250 250 250
Boiler weight
kg
273
293 303
301
306
306
345
353
350 408/415 453 460 407 545 487 700
Gas-outlet pipe di-
ameter
mm
152
152 152
152
152
152
152
152
152 152 152 152 152 152 160 160
Boiler height
mm
1180
1180 1180
1180
1180
1180
1260
1260
1260 1260 1410 1360 1260 1360 1380 1480
Boiler width
mm
590
590 590
590
590
590
680
680
680 680 680 770 680 770 680 770
Boiler depth
mm
845
845 1045
845
1045
1045
1045
1045
845 1045 1045 1045 1245 1245 1060 1390
Electric parts ingress
protection
IP 20
Electric input
W
0
50 50
50
50 50 50 50 50 50 50 50 50 50 50 70
Boiler effectiveness
% 80-89
Boiler class
3
Waste gas temperature
at nominal output
°C
208
208 225
230
225 240 230 250 210 230/225 250 245 255 245 260 240
Waste gas combustion
products flow weight
at nominal output
kg/s
0,010
0,012 0,014
0,014
0,015 0,017 0,017 0,022 0,012
0,015
0,018
0,022 0,022 0,025 0,025 0,035 0,035
Specified fuel
Dry wood with heating capacity 15 - 17 MJ.kg1, water content at least 12% - max. 20%, average 80 - 150 mm
Average fuel con-
sumption
kg.h
-1
3,5
3,8 5 5 6 7 7,2 10 3,8 6/7,2 10 10 13 13 18 18
Per heating season 1 kW = 1 stacked cubic meter
Maximum wood
length
mm
330
330 530
330
530
530
530
530
330 530 530 530 730 700 730 1000
Burning time at nomi-
nal output
hod.
2
2 3
2
3
2
3
2
2 3/2 3 3 3 3 2 3
Boiler water volume
l
45
45 58
45
58
58
80
80
64 80 90 110 89 141 93 171
Hydraulic pressure
drop
mbar
0,18
0,18 0,21
0,18
0,21
0,21
0,20
0,20
0,22 0,22 0,23 0,22 0,22 0,23 0,25 0,24
Equalising tank mini-
mum volume
l
500
500 500
500
500
500
500
500
500 500 750 750 750 750 1000 1000
Connecting voltage
V/Hz 230/50
Specified minimum temperature of water returning to boiler is 65°C when in operation.