3.5.3 For Windows systems, turn on the camera and when recording a
video, it is recommended to select a lower resolution, so as not to
occupy too much memo.
3.5.4 Use Quick Player to record videos. Select "New Movie
Recording" in the "File" menu, click 1 in the lower right picture to
select the camera, and then click 2 to sta recording.
2. How to deal with the positioning accuracy error > 2mm?
1) Control the result captured during the camera lens calibration process to have Score ≤0.5 and slight or no pattern deformation.
2) The origin card used for calibration should not be deformed or warped as it will aect the accuracy.
3) During the calibration process, honeycomb panels cannot be used. If there is a honeycomb panel, it needs to be covered with white
paper.
1. How to deal with the edge collision in Step 3.3 calibration camera alignment?
1) Check if absolute coordinates are selected.