Troubleshooting Guide
PROBLEM
CAUSE
CORRECTION
U.V. lamp will not light
DWS © 2019 • www.aquat.com
Sterile Water Sample Procedure
Fig 1
SUGGESTED PROCEDURE FOR OBTAINING
STERILE WATER SAMPLES:
Prior to taking the water sample, be sure to have on hand an
adequate supply of sterile bottles (as shown in Fig 1). These
sterile bottles should be obtained from a reputable laboratory
and should have been autoclaved and contained within a
plastic outer wrapping.
1. Prior to taking the sample, it is imperative that
the sample
valve, faucets, etc. be opened at full force for a complete three
and a half minutes.
2. After the valve has been left fully opened for three and
one half minutes, reduce the flow to a reasonable stream of
water. Flow to drain an additional three minutes.
3. Open the sterile bottle or sterile container being used.
Holding the cap in a down position, the operator should then
hold his breath while taking the sample so as to avoid oral
contamination of the sample. The operator must not allow his
finger to touch the inside of the cap or the neck of the bottle.
4. After the sample has been taken, the cap should be tightly
placed on the sample container.
5. The sample container should be placed in a plastic
wrapping, kept cool, and should be taken to the laboratory
for testing as soon as possible following the above procedure.
We recommend duplicate samples be taken at each test
station during each specific test so as to avoid loss of
sample through labor
atory error and to insure
reasonable validity thr
ough comparison.
Check with your local laboratory to assure proper
sampling and submittal procedure.
Check input voltages if below or above 110V
Install a voltage regulator
Electrical cord disconnected or outlet
defective
Check, replace
Defective UV Lamp
Defective Lamp Ballast
Loose open-circuit wire
Replace Lamp
Check output voltage. Replace
ballast
Trace out and repair
Leak at Quartz nipple
Defective or cracked O-Ring
O-Ring not seated properly
Cracked Quartz Sleeve
Replace O-Ring
Replace O-Ring
Replace Quartz Sleeve