TI072 400-072-000-C 2008-05-08 1/2
TI072
User guide
7-day Solar Programmable Wall Switch
The TI072 programmable wall switch has been designed to control lights and motors:
n Cut power at the circuit breaker to avoid electric shock.
o Remove the existing switch. (For a 3-way installation, identify and label the wire that is connected to
the “common” screw.)
p Install the new switch.
q Apply power at the circuit breaker.
SINGLE-SWITCH INSTALLATION
EXISTING 3-WAY INSTALLATION
Connect the LOAD wire on the TI072 to the “common” wire, which you identified when removing the old
switch. Connect the NEUTRAL wire to the neutral (white) wires. Connect the LINE and 3 WAY wires to the
two remaining wires. At the other 3-way switch, connect the jumper wire between the “common” screw and
the screw where the LINE wire of the TI072 is connected.
NEW 3-WAY INSTALLATION
The TI072 will turn the lights on at sunset and turn them off at 11:00 pm by default. If these settings are
appropriate for you, you only need to set the time and date (see shaded zone in the menu flowchart sheet).
If the switch’s sunset time does not correspond to the actual sunset time, see sections 5.3.3 and 5.3.4.
5.1 Mode Menu
You can use the Mode menu to select one of the three modes of operation (see sections 5.1.1 to 5.1.3).
5.1.1 Manual Mode
In Manual mode, the TI072 operates like a regular switch. To turn the lights on or off, briefly
press the main button. The icon appears when the switch is in Manual mode.
5.1.2 Automatic Mode
In Automatic mode, the TI072 turns the lights on or off according to the set programs (see
Section 5.4). The icon as well as the current program number are displayed.
5.1.3 Random Mode
In Random mode, the TI072 has no specific times to turn the lights on or off. This mode is
designed to give the impression the house is occupied during your absence. It is similar to the
Automatic mode except there is no fixed program. The programs are automatically set to
different times by the TI072 every day. The icon appears when the switch is in Random mode.
The first “On” program occurs at sunset. Each “On” program lasts between 1 hour and 1
hour and 30 minutes; each “Off” program lasts between 15 and 30 minutes. The last “Off”
program occurs between 10:30 pm and midnight.
5.1.4 Temporary Override
When the TI072 is in Automatic or Random mode, you can press the main button at any time to override the
default state for the current program. The light will turn off if they are on and vice versa. The icon (On or Off)
of the new state flashes to indicate that the state is temporary. The new state is maintained until you press
the main button again or till the next “On” or “Off” program.
5.2 Time Menu
The time display flashes on the screen when the time has not yet been set or after a 4-hour power outage.
Use the Time menu to select the time format (12-hour or 24-hour) and to set the clock and date.
NOTE: The date is used to determine the sunset and sunrise times.
n
Applications
1.
Load types Maximum load Examples
Lights and resistive loads
(except tungsten)
1800 W (15 A @ 120 V)
fluorescent lights
compact fluorescent lights (CFL)
electronic ballasts
sodium lamps
block heaters
Tungsten lights 1440 W (12 A @ 120 V)
incandescent lights
halogen lights
Motors 1 hp
pool filter pumps
•fans
o
Installation
2.
black (LINE)
yellow (3 WAY)
120
VAC
blue (LOAD)
white (NEUTRAL)
black
white
black
white
120 VAC
red
jumper
black
white
black (LINE)
yellow (3 WAY)
blue (LOAD)
white (NEUTRAL)
black
white
black
white
three-way
switch
120
VAC
black
white
black
white
black
white
black (LINE)
yellow (3 WAY)
blue (LOAD)
white (NEUTRAL)
single-pole
switch
p
Quick Start-up
3.
Set the time and date before using the timer for the first time.
q
Operation
4.
r
Setup Menus
5.
Press the main button for 3 seconds to enter the setup menus. Refer to
the menu flowchart sheet on how to navigate the menus.
The icon indicates the current
program has been activated at sunset.
The icon indicates the current
program has been activated at sunrise.
The LED illuminates when the load
state is on.
Briefly press this button to turn the
lights on or off. See “Temporary
Override” in Section 5.1.4.
Press for 3 seconds to enter the
setup menus.
Indicates the mode of operation
(see Section 5.1)
Indicates the current program
Indicates the load on/off state
Indicates the time and day
Indicates the keypad is locked
(see Section 6)
Press this button to display today’s sunrise time.
Press this button to display today’s sunset time.
(3 sec.)
NOTE:
This switch cannot be used if there is no neutral wire
(white wires joint together) inside the electrical box.
400-072-000-C ENG.fm Page 1 Thursday, May 8, 2008 2:45 PM

Questions and Answers

Aube Technologies TI072 Specifications

General IconGeneral
Voltage120/240 VAC
Current Rating15 A
Number of Programs7
Battery BackupNo
DisplayLCD
MountingWall
TypeProgrammable

Summary

Applications

Load Types and Examples

Lists load types, maximum loads, and corresponding examples for the wall switch.

Installation Guide

Single-Switch Wiring

Wiring diagram and instructions for a single-switch installation.

3-Way Wiring

Wiring diagrams for existing and new 3-way installations.

Quick Start-up

Initial Time and Date Setting

Set the time and date before first use for accurate operation.

Operation and Setup

Operation Modes

Select between Manual, Automatic, and Random modes for light control.

Temporary Override

Temporarily change the light state from the programmed schedule.

Time Menu Settings

Configure time format, clock, and date for accurate scheduling.

Configuration Menu

Backlight Mode

Adjust screen backlight intensity and behavior.

Automatic Daylight Savings

Enable or disable automatic DST changeover.

Latitude and Longitude

Set geographical coordinates for accurate sunset/sunrise times.

Correction Factor

Apply a time zone adjustment for sunrise/sunset accuracy.

Program Menu

Setting Programs

Define ON/OFF times for automatic mode.

Selecting Program Number

Choose a program number (1-21) for ON or OFF events.

Setting Program Days

Specify days of the week for a program to be active.

Setting Program Start Time

Set program start time to specific, sunset, or sunrise time.

Keypad Lock

Locking;Unlocking Keypad

Procedure to lock or unlock the keypad.

Reset to Default Settings

Factory Reset Procedure

Steps to restore the switch to its original factory settings.

Troubleshooting

Display Issues

Addresses faded display or disappearance when toggling.

Sunset;Sunrise Inaccuracy

Solutions for inaccurate sunset or sunrise times.

Specifications

Electrical Ratings

Details supply voltage, frequency, and maximum load.

Operating Conditions

Specifies temperature ranges for operation and storage.

Power Outage Behavior

Describes how settings are retained after power loss.

Warranty Information

Product Warranty

Details the three-year warranty coverage and limitations.

Technical Assistance

Contact Information

Provides contact details for customer support and website.

Menu Flowchart

Legend and Navigation

Explains symbols and button actions in the menu flowchart.

Menu Structure Overview

Visual representation of menu navigation and settings.

Configuration Settings

Details settings for backlight, DST, latitude, longitude, and correction factor.

Program Settings

Flowchart for setting program number, days, and start time.

Location Coordinates

Canadian City Coordinates

Table of latitude, longitude, and correction factors for Canadian cities.

USA City Coordinates

Table of latitude, longitude, and correction factors for US cities.

Mexico City Coordinates

Table of latitude, longitude, and correction factors for Mexican cities.

Dominican Republic Coordinates

Table of latitude, longitude, and correction factors for Dominican cities.

Related product manuals