The TI035 programmable wall switch has been designed to control lightings and motors:
NOTE: This switch cannot be used if there are not at least 2 white wires joined by a
connector inside the electrical box.
1) Cut power at the circuit breaker to avoid electric shock.
2) Remove the existing switch.
3) Install the new switch.
4) Apply power at the circuit breaker.
Applications
Load type Maximum load Examples
Resistive load
2400 W
(20 A @ 120 V)
incandescent lights
halogen lights
block heater
Inductive load
2400 W
(20 A @ 120 V)
fluorescent lights
compact fluorescent lights (CFL)
sodium lamps
electronic ballasts
Motor 1 hp
pool filter pumps
fans
Installation
120 VAC (line)
white (neutral)
black (line)
blue (load)
Load
TI035
Installation and User Guide
Programmable Wall Switch
69-2776EF-03

Questions and Answers:

Aube Technologies TI035 Specifications

General IconGeneral
BrandAube Technologies
ModelTI035
CategorySwitch
LanguageEnglish

Summary

Applications

Installation

Power-On

Selecting the Operating Mode

Manual Mode

Operates as a regular switch, with lights turned On or Off by briefly pressing the switch door.

Automatic Mode

Follows programmed schedule. Temporary overrides are possible by briefly pressing the switch door.

Setting the Clock

Sunset/Sunrise Program

Defining Sunset/Sunrise Parameters

Enter Latitude, Longitude, Day #, nor/Ad, and Lc values to configure the program.

Programming Sunset/Sunrise Parameters

Use CODE button to select parameters and HOUR/MIN to adjust values for accurate timing.

Programming the Schedule

Clearing Programmed Schedule Times

Press PGM to select time, then CODE to erase. Sunset/sunrise times may revert if programmed.

Technical Specifications

Troubleshooting

Display Issues (Blank or Faded)

Check circuit breaker, ON/OFF selector, reset switch, or ambient temperature for display problems.

Program Functionality Issues

Ensure MAN/AUTO mode is active and check 12-hour PM display and program settings.

Load & Override Behavior Issues

Install snubbers for inductive loads or set P1 OFF to midnight to manage overrides.