- 21 -
of the cable easier as shown in Fig 27. In order to prevent the cables from coming loose when
pulling on them during box installation, make sure all cables are securely tightened by a
screw driver. Also, make sure there are no small wires touching the other terminals as this
may cause a short circuit.
Table 1. Wiring to the controller
Color code of wire
Terminal
Brown power cable
1
Black power cable
2
Black jumper cable
2 & 4
Blue steam control cable
3
Green (brew pump control cable)
5
White RTD jumper cable
6 & 7
Clear RTD cables
7 & 8
White steam control cable
9
White and Red cables from SSR
9&10
Fig 26. Detailed view of controller connections.