ENGLISH VERSION
All the setted parameter can be saved in the memo-
rizer to be used in the same mode in the future. Short
press <”MENU”> into function selecting: Press “BACK”,
“NEXT” or turn any knob of “PARA” to go forward or
back. Short press “ENTER” into relevant function par-
aemter setting. Turn any knob of “PARA” to set relevant
parameter; short “ENTER” to conrm, and “ESC” key to
escape.
MainMenu:
1. XoverSubMenu: 1. Load Program
2. Store Program
3. Erase Program
2. Programcopy: Turn any knob of “PARA” to se-
lect Program Copy.
3.ChannelCopy: Turn any knob of “PARA” to se-
lect each Channel Copy.
4.InputSubMenu: Turn any knob of “PARA” to se-
lect Input Source of Input
Channel A-d.
5.SecuritySubMenu: Turn any knob of “PARA” to set
password.
6.SystemSubMenu: 1. BacklightSetup: Set the LCD
backlight for long display or auto close for 25 seconds.
2. SystemInfo: Press “ENTER”
to check System Info.
3. Temperature: Turn any knob
of “PARA” to set temperature.
4.FilterDispay: Turn any knob
of “PARA” to select BW/Q.
5. SceneChange:Hotkey Ena-
ble/Disable
6. SceneKeySetup
7. Wi Factory Reset: Turn
any knob of “PARA” to select
YES/NO.
SYSTEMPARAMETERSETTING: