The information contained in this document is non-contractual. Auer reserves the right to modify the technical specications or characterisitcs of any of their appliances without prior notice.
If your auer Heat Pump is flashing 3 times, it indicates that the power supply voltage is outside of the authorized range of operation. To resolve this, check the voltage on the three-phased network and ensure the power supply from the general counter to the Heat Pump is compliant. If issues persist, contact your electricity provider to ensure proper sizing of the electrical network.
P
Peggy PerezAug 4, 2025
What to do if my auer HRC70 35/2 t Heat Pump is flashing 9 times?
W
wheelerjamesAug 5, 2025
If your auer Heat Pump is flashing 9 times, it indicates an imbalance of phases. Check the voltage on the three-phased network and ensure the power supply from the general counter to the Heat Pump is compliant. If problems continue, contact your electricity provider.
J
Jack DiazAug 12, 2025
What does it mean when my auer HRC70 35/2 t is flashing 2 times?
D
Debra ChenAug 12, 2025
If your auer Heat Pump is flashing 2 times, it means the phases are reversed. You can fix this by reversing the two phases on the power supply of the starter.
C
christinaloweAug 20, 2025
What to do if my auer Heat Pump is flashing 6 times?
M
Mitchell FarmerAug 20, 2025
If your auer Heat Pump is flashing 6 times, it indicates that the start-up process is incomplete. Check the power supply to the Heat Pump before and during start-up, ensuring it is not lower than 350 volts.